Warning: fopen(/home/virtual/arm/journal/upload/ip_log/ip_log_2025-04.txt): failed to open stream: Permission denied in /home/virtual/lib/view_data.php on line 95 Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 96 Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study
  • KARM
  • Contact us
  • E-Submission
ABOUT
ARTICLE TYPES
BROWSE ARTICLES
AUTHOR INFORMATION

Articles

Original Article

Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

Annals of Rehabilitation Medicine 2014;38(1):84-93.
Published online: February 25, 2014

Department of Physical Medicine and Rehabilitation, Chung-Ang University College of Medicine, Seoul, Korea.

Corresponding author: Don-Kyu Kim. Departments of Physical Medicine and Rehabilitation, Chung-Ang University College of Medicine, 102 Heukseok-ro, Dongjak-gu, Seoul 156-755, Korea. Tel: +82-2-2225-1535, Fax: +82-2-2225-1579, miryjy@hanmail.net
• Received: May 16, 2013   • Accepted: October 1, 2013

Copyright © 2014 by Korean Academy of Rehabilitation Medicine

This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 7,441 Views
  • 155 Download
  • 69 Web of Science
  • 60 Crossref
  • 74 Scopus
prev
  • Objective
    To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer.
  • Methods
    Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35° angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis.
  • Results
    The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963).
  • Conclusion
    Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength.
Assessment of muscle strength is one of the important predictive factors not only of neurological diseases or musculoskeletal disorders, but also of the physical function of elderly people. In particular, the lower extremity muscle strength is known as an important indicator of gait and physical functions of the elderly population [1,2]. Most recently, handgrip strength has been known to be highly associated with the lower extremity muscle power, the knee extensor torque and the cross-sectional area of the calf muscles among the elderly [3,4], and accordingly, has been used for clinical or research purposes in the geriatric field. However, this method is not for a direct measurement of the lower extremity muscle strength and many confusing factors affect the reliability and validity of the handgrip strength method. Moreover, the absence of a standard measurement method has limited its clinical applications [5,6].
Isokinetic dynamometer has been used as a reliable and objective equipment for measuring the lower extremity muscle strength [7-10]. However, it is expensive, requires separate space, is not portable, requires a long measurement time and a trained rater, and may impose a heavy cost burden on researchers or patients. Accordingly, this method has been used for research purposes, but not often for large-scale studies.
In addition to the isokinetic dynamometer, the fixed dynamometer and hand-held dynamometer (HHD), which are portable devices, have been used for muscle strength measurement [11]. The fixed dynamometer has been used for research in a few studies, and has been primarily used for the fixation of dynamometer in order to avoid rater interference. However, it cannot be used for portable purposes because it needs to be fixed on to a column or wall in order to anchor it; further, it requires additional equipment and therefore is seldom used for research or clinical purposes at present. In addition, the direction of muscle strength measurement and dynamometer should be placed on the same line as the anchor; thus, there are limitations in its measurement position, joint angle and measurement site. Accordingly, its reliability is inferior to that of HDD in measuring the strength of some muscles [12,13]. In comparison, HHD can be directly attached to a specific body area in any position; however, it also has limitations in its measurement position, joint angle, measurement site, measurement type, muscle contraction type and speed. These limitations are also seen in the fixed dynamometer. Moreover, it has rater factor problems, such as the muscle strength and proficiency of the raters, which can affect the test results [14]. According to the systematic literature review conducted by Stark et al. [15], no standard HHD method that can verify the appropriate levels of reliability and validity has been established yet; hence, it cannot completely replace the isokinetic dynamometer test in clinical cases. Nevertheless, Thorborg et al. [16] reported that the HDD test fixating the device for measuring the muscle strength near the hip joint had reduced the rater errors that were observed with HHD and also had improved its reliability.
When the reliability of HDD, which is easy to carry and use, is enhanced and its standard protocol is available, it can be a highly recommendable method of muscle strength assessment. In this study, the peak knee extensor torque was measured using the typical non-fixed HHD method of holding the HDD and the fixed method; then, the results were compared with those of the isokinetic dynamometer method in order 1) to confirm their validity, 2) to assess their reliability through a test-retest method, and 3) to confirm the difference in the knee extensor muscle strength results of the HDD test, according to the measurement position. Based on the outcomes, the ideal measurement method and position are suggested in this study by confirming the reliability and validity of the HHD test, which is for measuring the knee extensor muscle strength.
The study protocol was approved from the Institutional Review Board of Chung-Ang University Hospital. The subjects were recruited through advertisements and were informed of the purpose and nature of this study before they signed the written consent form.
Subject
Of the 30 recruited women in their 20s and 30s, three who were suffering from musculoskeletal diseases at the time of their recruitment; who had undergone musculoskeletal surgery that could have affected both their legs; who had abnormal physical examination findings in their knee or hip joint; who had a history of diabetes, thyroidism or hypertension; or who performed vigorous exercises that could affect their muscle strength during the study period were excluded from this study. Eventually, 27 healthy young women were eligible in this study. The mean age of the subjects was 23.9±2.9 years; their mean height, 162.0±5.1 cm; their mean weight, 51.4±5.1 kg; their mean muscle mass which was measured by a bioimpedance analysis, 20.5±2.0 kg; and their mean body mass index, 19.6±1.5 kg/m2. All the subjects identified their right legs as their dominant legs.
Methods
The subjects participated in this study twice, with a one-week interval in between. Three trained male raters of the isokinetic dynamometer (Biodex System 3; Biodex Medical Systems, New York, NY, USA) and HHD (JTECH Medical, Salt Lake City, UT, USA) tests measured the respective peak isometric torque (unit, Nm) and the peak muscle force (unit, N) of both of the subjects' knee extensors. On the first day, one rater conducted the isokinetic dynamometer test thrice; and after the HHD was fixed, each of the three raters made measurements three times. On the second day, the HHD was fixed and one of the three raters made three measurements, and then each of the three raters made three measurements using the non-fixed HDD (Fig. 1). The isokinetic dynamometer test and the HHD test were randomly conducted. Each measurement was conducted with a five-minute interval in order to prevent muscle fatigue [17]. All the tests were conducted 1) in the sitting and supine positions and 2) on the right and left legs.

Isokinetic dynamometer test

For the isokinetic dynamometer test, the subject was seated on a dynamometer chair, and the lateral femoral condyle of her knee joint was aligned with the rotating axis of the dynamometer. Then, her knee joint was flexed from the maximum extension angle by 35° before her ankle was fixed with a Velcro strip on the rotating axis of the isokinetic dynamometer in order to measure the isometric peak torque (Nm) of the knee extensor (Fig. 2). The flexion position was chosen after considering the study results of high-level surface EMG activity with the knee joint that was flexed by 35° [18] and the favorable reliability of the test results with the stable subject's knee joint that was flexed by 35° in the HHD test for the knee extensor torque [19,20].

HHD test

Similar to the isokinetic dynamometer method, the subject was in a sitting or supine position, with her knee joint flexed from the maximum extension angle by 35°, after which the HDD was positioned in the area that was fixed with the ankle belt in the isokinetic dynamometer test in order to measure the isometric peak flexion force (N) of both knee joints (Fig. 3). Similar to the isokinetic dynamometer test, the HDD was fixed in the area that was 2 finger breadths above the ankle joint and distal to the tibia using a belt or the rater's hand. When the fixed HHD was used, it was fixed at the lower edge of the slanting surface of the slanting box using a belt. The slanting surface was firmly fixed on the bottom of the box during the test to prevent any movement or lifting (Fig. 3). As the same HDD was used in both the fixed and non-fixed methods, errors that could have occurred due to the discrepancy in the type of HHD were prevented.
In the HHD test, the intra-rater reliability was assessed by comparing the results of the first- and second-day tests, which were conducted by the same rater. To assess the inter-rater reliability in the fixed HHD method, each of the three raters measured the peak knee extensor force of both legs three times on the first day. To assess the inter-rater reliability in the non-fixed HHD method, each of the three raters measured the peak knee extensor force of both legs three times on the second day.
Statistical analysis
To compare all the muscle forces (N) that were measured using the HHD with the peak torque (Nm), which was measured with the isokinetic dynamometer, the length (m) between the knee joint and the ankle was measured and then multiplied by the muscle force (N), which was measured using the HHD, in order to calculate the peak torque (Nm).
To confirm the validity of the peak knee joint torque values that were measured using the fixed and non-fixed HHD tests, the values that were measured in the isokinetic dynamometer test were compared with the results of the paired samples t-test and Pearson correlation analysis.
To assess the reliability of the fixed HHD test, the intraclass correlation coefficient (ICC) and the standard error of measurement were calculated using the test-retest method. To confirm and compare the reliability of the fixed HHD test with the non-fixed HHD test, the interrater ICC and the standard error were calculated and analyzed.
To confirm the difference in the peak knee extensor torque values that were obtained from the fixed HHD, non-fixed HHD, and isokinetic dynamometer tests in the sitting and supine positions, as well as to analyze the validity of the tests, a paired samples t-test and a Pearson correlation analysis were conducted. For statistical analysis, SPSS ver. 17.0 (SPSS Inc., Chicago, IL, USA) was used.
The mean peak torque values that were obtained from the HHD method in the sitting and supine positions were less than those from the isokinetic dynamometer method. However, in the paired samples t-test, no statistically significant difference between the fixed HHD method and the isokinetic dynamometer method was observed. However, the mean peak torque values of the knee extensor, which were obtained from the non-fixed HHD method, showed a statistically significant difference from those obtained from the isokinetic dynamometer method, excluding the left leg value that was measured in the sitting position (Table 1). In the Pearson correlation analysis of the isokinetic dynamometer test results (Table 2), the peak torque values (right r=0.806 and left r=0.524) of both knee extensors, which were measured using the fixed HHD method in the supine position, showed a high correlation with those from the isokinetic dynamometer method (p<0.05). However, in the sitting position, only the right leg value (r=0.473) showed a significant correlation (p<0.05). In the non-fixed HHD method, only the left knee joint value in the supine position showed a significant Pearson correlation coefficient value (r=0.384, p<0.05), whereas the rest did not show significant values (Fig. 4).
The inter-rater ICC values in the fixed HHD method ranged from 0.952 to 0.984, and those in the non-fixed HHD method were from 0.940 to 0.963. Thus, both methods demonstrated significantly high reliability; yet, the fixed HHD method values were higher than the non-fixed HHD method values (Table 3). The intra-rater ICC values in the fixed HHD method ranged from 0.968 to 0.985, indicating a high reliability (Table 4).
The mean isometric peak torque values of both knee extensors in the supine position were higher than those in the sitting position in both the HHD and isokinetic dynamometer tests (Table 1). The paired samples t-test analysis showed that the peak torque of the right knee extensor values of both the isokinetic dynamometer and fixed HHD tests in the supine position were significantly greater than those in the sitting position, whereas the peak torque of the left knee extensor did not show a statistically significant difference. In the non-fixed HHD test, the values of the peak torque of both knee extensors in the supine position were significantly greater than those in the sitting position (Table 1). As a result of the Pearson correlation analysis, the correlation coefficients of the fixed HHD measurements obtained in the supine position were 0.806 (right) and 0.524 (left), which show a high correlation with those of the isokinetic dynamometer measurements (p<0.05). However, in the sitting position, only the right leg values showed such a correlation, with a 0.473 correlation coefficient (p<0.05) (Table 2). In the Pearson correlation analysis, only the non-fixed HHD measurements in the supine position from the left leg showed a correlation with the isokinetic dynamometer measurements, with a 0.384 correlation coefficient (p<0.05) (Table 2).
HHD is inexpensive, easy to carry and use. However, many factors affect the test results, and its reliability is known to not be very high. In this study, a test method with the advantage of the HHD and of enhanced reliability is suggested and compared with the isokinetic dynamometer method in order to confirm its validity. When the HHD was fixed on the leg using a specially prepared band, higher validity and reliability were observed than when the rater held it with one hand. In terms of the position, higher validity was observed in the supine position than in the sitting position.
Other than the HHD fixation method, which was an independent variable and the test position, factors that could have affected the reliability of the HHD test results were attempted to be controlled in this study. In the HHD test, the make-test is the method with which the subject applied a force to the HHD while the rater was trying not to move it. The break-test is the method with which the rater attempted to overcome the force that the subject applied to his/her ankle using the HHD. The reliability of the make-test is known to be higher than that of the break-test [21]; thus, the non-fixed or hand-held method was measured using the make-test method in this study. The reliability of the HHD test is known to increase when the rater is stronger than the subject [22]. In this study, male raters who had strong muscle forces and were trained with the HDD test were selected to control their muscle force and proficiency. Through the HHD fixation, the factors which could affect the rater or the subject in the non-fixed method were excluded. When the knee extensor strength values in the fixed and non-fixed HHD tests were compared with those in the isokinetic dynamometer test, no statistically significant difference was observed between the fixed HHD and isokinetic dynamometer; however, most of the non-fixed HHD test values were confirmed to have significantly differed from those of the isokinetic dynamometer test. Unlike the isokinetic dynamometer and fixed HHD tests, the non-fixed HHD test conveyed a high peak torque value in the left leg. The reliability of the test-retest method was high regardless of the fixation type, but that of the fixed method was confirmed to have been higher than that of the non-fixed method. The difference that was observed between the fixed and non-fixed methods might have been due to systemic error [23]. A systemic error is a bias that consistently occurs in a specific direction, revealing a correspondence between the measured value and the true value. When the rater resists the subject's leg force to maintain his/her measurement position, a systemic error increases in case the rater's force against the subject is not strong enough. After the HHD was fixed on the portable device using a belt, the systemic error decreased and the validity was enhanced, unlike in the non-fixed HHD method.
In the fixed HHD test with the 35° flexed knee joint, the values in the supine position and of the right leg showed the greatest correlation with those of the isokinetic dynamometer test. With the 90° knee joint, the isometric extensor muscle force in the sitting position was reportedly 10.6% greater than in the supine position [18]; however, in the study with the 35° flexed knee joint, higher measured values (right 5.82% and left 10.23%) were obtained in the supine position than in the sitting position. This might have been due to the optimal muscle length at the moment of the peak muscle force [24] and to the muscle length, which changes according to the angles of the knee and hip joints in the sitting or supine positions. According to the previous study, the isometric muscle force of the rectus femoris muscle was confirmed to have been greater with the 35° flexed knee joint than with the 75° flexed knee joint, through the measurement of the electromyography signals [25]. In addition, the reliability of the values in the supine position was higher than in the sitting position, because the supine position was more convenient than the sitting position for the elderly subjects [26] and moreover, it was deemed more stable in maintaining the measurement position during the test period. To form a definitive conclusion, further studies on the position may be needed in the future.
The accuracy of the right leg measurement was superior to that of the left leg measurement because the right leg was the dominant leg in all the subjects. However, no standard on the differentiation of the dominant leg from the non-dominant leg could be prepared in this study. Before the reliability of the determination of the dominant leg is evaluated, an accurate method of determining the dominant leg should be established; hence, additional validation studies may be needed for left leg dominance.
One of the limitations of this study is that the subjects were limited to young women. As a preliminary study to investigate the reliability and validity of the HHD test according to the position and type of the fixation, the subjects were restricted to young women in order to control the variables and to simplify the study structure. To generalize the results of this study, additional studies with both men and women, in addition to the elderly who clinically need measurement of their leg muscle strength, may be needed. The other limitation of this study is the random allocation of measurement. On the first day, the isokinetic dynamometer test and the fixed HHD test were randomly conducted; and on the second day, the fixed HHD test and the non-fixed HHD test were performed. If the fixed HHD, non-fixed HHD, and isokinetic dynamometer tests had been randomly conducted, the results of this study might have been more reliable. However, to investigate the inter-rater reliability of the test-retest fixed HHD method, the fixed HHD test was conducted over two days, and the overall quantity of exertion among the subjects and the raters was evenly distributed, taking into consideration their muscle fatigue and concentration deterioration. Nevertheless, considering the high intra-rater reliability (ICC, 0.968-0.985) of the test-retest result of the fixed HHD method and the high Pearson correlation results of the fixed HHD test, which was conducted on the second day (results not shown), along with the isokinetic dynamometer test, the reliability was deemed to have not been significantly affected.
In measuring the knee extensor strength with an HHD, the fixation of HHD during measurement in the supine position was confirmed to increase the reliability and validity in measuring quadriceps strength in this study. Because the fixed HHD method is not only more economical than the isokinetic dynamometer method, but is also easy to carry and use, it may be able to use in place of the isokinetic dynamometer method in clinical or research settings.

No potential conflict of interest relevant to this article was reported.

  • 1. Bean JF, Kiely DK, Herman S, Leveille SG, Mizer K, Frontera WR, et al. The relationship between leg power and physical performance in mobility-limited older people. J Am Geriatr Soc 2002;50:461-467.
  • 2. Suzuki T, Bean JF, Fielding RA. Muscle power of the ankle flexors predicts functional performance in community-dwelling older women. J Am Geriatr Soc 2001;49:1161-1167.
  • 3. Lauretani F, Russo CR, Bandinelli S, Bartali B, Cavazzini C, Di Iorio A, et al. Age-associated changes in skeletal muscles and their effect on mobility: an operational diagnosis of sarcopenia. J Appl Physiol 2003;95:1851-1860.
  • 4. Al Snih S, Markides KS, Ottenbacher KJ, Raji MA. Hand grip strength and incident ADL disability in elderly Mexican Americans over a seven-year period. Aging Clin Exp Res 2004;16:481-486.
  • 5. Brinker MR, Cuomo JS, Popham GJ, O'Connor DP, Barrack RL. An examination of bias in shoulder scoring instruments among healthy collegiate and recreational athletes. J Shoulder Elbow Surg 2002;11:463-469.
  • 6. Incel NA, Ceceli E, Durukan PB, Erdem HR, Yorgancioglu ZR. Grip strength: effect of hand dominance. Singapore Med J 2002;43:234-237.
  • 7. Knapik JJ, Wright JE, Mawdsley RH, Braun JM. Isokinetic, isometric and isotonic strength relationships. Arch Phys Med Rehabil 1983;64:77-80.
  • 8. Farrell M, Richards JG. Analysis of the reliability and validity of the kinetic communicator exercise device. Med Sci Sports Exerc 1986;18:44-49.
  • 9. Drouin JM, Valovich-mcLeod TC, Shultz SJ, Gansneder BM, Perrin DH. Reliability and validity of the Biodex System 3 Pro isokinetic dynamometer velocity, torque and position measurements. Eur J Appl Physiol 2004;91:22-29.
  • 10. Feiring DC, Ellenbecker TS, Derscheid GL. Test-retest reliability of the Biodex isokinetic dynamometer. J Orthop Sports Phys Ther 1990;11:298-300.
  • 11. Toonstra J, Mattacola CG. Test-retest reliability and validity of isometric knee flexion and extension measurement using three methods of assessing muscle strength. J Sport Rehabil 2012;9 04 [Epub]. http://journals.humankinetics.com/jsr-technical-reports/jsr-technical-reports/testndashretest-reliability-and-validity-of-isometric-knee-flexion-and--extension-measurement-using-3-methods-of-assessing-muscle-strength
  • 12. Scott DA, Bond EQ, Sisto SA, Nadler SF. The intra- and interrater reliability of hip muscle strength assessments using a handheld versus a portable dynamometer anchoring station. Arch Phys Med Rehabil 2004;85:598-603.
  • 13. Kollock RO Jr, Onate JA, Van Lunen B. The reliability of portable fixed dynamometry during hip and knee strength assessments. J Athl Train 2010;45:349-356.
  • 14. Keating JL, Matyas TA. The influence of subject and test design on dynamometric measurements of extremity muscles. Phys Ther 1996;76:866-889.
  • 15. Stark T, Walker B, Phillips JK, Fejer R, Beck R. Hand-held dynamometry correlation with the gold standard isokinetic dynamometry: a systematic review. PM R 2011;3:472-479.
  • 16. Thorborg K, Bandholm T, Holmich P. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable. Knee Surg Sports Traumatol Arthrosc 2013;21:550-555.
  • 17. Woods S, Bridge T, Nelson D, Risse K, Pincivero DM. The effects of rest interval length on ratings of perceived exertion during dynamic knee extension exercise. J Strength Cond Res 2004;18:540-545.
  • 18. Maffiuletti NA, Lepers R. Quadriceps femoris torque and EMG activity in seated versus supine position. Med Sci Sports Exerc 2003;35:1511-1516.
  • 19. Walsworth M, Schneider R, Schultz J, Dahl C, Allison S, Underwood F, et al. Prediction of 10 repetition maximum for short-arc quadriceps exercise from hand-held dynamometer and anthropometric measurements. J Orthop Sports Phys Ther 1998;28:97-104.
  • 20. Knapik JJ, Wright JE, Mawdsley RH, Braun J. Isometric, isotonic, and isokinetic torque variations in four muscle groups through a range of joint motion. Phys Ther 1983;63:938-947.
  • 21. Stratford PW, Balsor BE. A comparison of make and break tests using a hand-held dynamometer and the Kin-Com. J Orthop Sports Phys Ther 1994;19:28-32.
  • 22. Deones VL, Wiley SC, Worrell T. Assessment of quadriceps muscle performance by a hand-held dynamometer and an isokinetic dynamometer. J Orthop Sports Phys Ther 1994;20:296-301.
  • 23. Taylor JR. An introduction to error analysis: the study of uncertainties in physical measurements. 2nd ed. Sausalito, CA: University Science Books; 1999.
  • 24. Visser JJ, Hoogkamer JE, Bobbert MF, Huijing PA. Length and moment arm of human leg muscles as a function of knee and hip-joint angles. Eur J Appl Physiol Occup Physiol 1990;61:453-460.
  • 25. Babault N, Pousson M, Michaut A, Van Hoecke J. Effect of quadriceps femoris muscle length on neural activation during isometric and concentric contractions. J Appl Physiol 2003;94:983-990.
  • 26. Martin HJ, Yule V, Syddall HE, Dennison EM, Cooper C, Aihie Sayer A. Is hand-held dynamometry useful for the measurement of quadriceps strength in older people? A comparison with the gold standard Biodex dynamometry. Gerontology 2006;52:154-159.
Fig. 1
Flow chart represents a process of the study.
arm-38-84-g001.jpg
Fig. 2
Study participant positioning for isokinetic dynamometer. (A) Sitting position and (B) supine position.
arm-38-84-g002.jpg
Fig. 3
Study participant positioning for fixed and non-fixed HHD methods. (A) Fixed HHD method with sitting and supine position was observed. (B) Non-fixed HHD method with sitting and supine position was observed.
arm-38-84-g003.jpg
Fig. 4
Correlation of fixed HHD and non-fixed HHD methods (x-axis) with isokinetic dynamometer (y-axis) in a scatter diagram. HHD, hand-held dynamometer; Rt., right; Lt., left. *p<0.05 was considered significant.
arm-38-84-g004.jpg
Table 1
Descriptive statistics of fixed and non-fixed HHD isokinetic dynamometer (unit, Nm)

HHD, hand-held dynamometer; Rt., right; Lt., left; SD, standard deviation.

a)p<0.05 difference between the result of supine position and seat position. b)p<0.05 difference between the result of isokinetic dynamometer and non-fixed HHD. c)p<0.05 difference between the result of fixed HHD and non-fixed HHD.

arm-38-84-i001.jpg
Table 2
Pearson correlation coefficient (r) between fixed HHD and non-fixed HHD methods according to isokinetic dynamometer

HHD, hand-held dynamometer; Rt., right; Lt., left.

*p<0.05 was considered significant.

arm-38-84-i002.jpg
Table 3
ICC and SEM of fixed HHD and non-fixed HHD methods by three testers

HHD, hand-held dynamometer; ICC, intraclass correlation coefficient; SEM, standard error of measurement; Rt., right; Lt., left.

arm-38-84-i003.jpg
Table 4
Intra-rater reliability of fixed HHD method

HHD, hand-held dynamometer; ICC, intraclass correlation coefficient; SEM, standard error of measurement; Rt., right; Lt., left.

arm-38-84-i004.jpg

Figure & Data

References

    Citations

    Citations to this article as recorded by  
    • Monitoring hamstring and quadriceps strength using handheld dynamometry in patients after ACL reconstruction: A prospective longitudinal study
      Wouter Welling, Jan Paalman, Ralph Speerstra, Albert Van Houten, Roy Hoogeslag
      Journal of Orthopaedics.2025; 59: 128.     CrossRef
    • Inter-rater and intra-rater reliability of belt-stabilized hand-held dynamometer using make test in lower extremity muscle strength assessment among healthy adults
      Reil Vinard S. Espino, Consuelo Gonzalez-Suarez, Lewis A. Ingram, Ivan Neil B. Gomez, Kris Anthony T. Agarao, Jazzmine Gale Flores, Nicole Bulseco
      International Journal of Osteopathic Medicine.2025; 56: 100753.     CrossRef
    • Handheld Dynamometry Testing During Dialysis: Intrarater and Interrater Reliability Study
      Eva Segura-Ortí, Anna Junqué-Jiménez, Valentin Dubuis, Maycon M. Reboredo, Vicente Benavent-Caballer, Noemi Valtueña-Gimeno, Fabricio Sciammarella Barros, Daniela Thomé Silva, Francisco J. Martinez-Olmos
      Journal of Renal Nutrition.2025;[Epub]     CrossRef
    • Lower extremity return to sport testing: A systematic review
      Traci Smiley, Johnathan Dallman, Rachel Long, Mason Kapple, Levi Aldag, Anthony Mok, Christopher Bernard, Kyle Martin, Lisa Vopat, Bryan Vopat
      The Knee.2024; 50: 115.     CrossRef
    • Changes in rehabilitation students’ clinical placement and clinical competence at graduation during the COVID-19 pandemic: A pilot study
      Ikuo Motoya, Shigeo Tanabe, Yuichi Hirakawa, Masanobu Iwai, Kazuya Takeda, Soichiro Koyama, Yoshikiyo Kanada, Nobutoshi Kawamura, Mami Kawamura, Hiroaki Sakurai
      Work.2024; 78(2): 267.     CrossRef
    • Balance and strength measures are associated with incident dementia in older men
      Jack Paterson, Michelle Trevenen, Keith Hill, Osvaldo P. Almeida, Bu B. Yeap, Jonathan Golledge, Graeme J. Hankey, Leon Flicker
      Aging and Health Research.2024; 4(3): 100199.     CrossRef
    • Association Between Protocols of the Sit-to-Stand Test and Lower Limb Muscle Force Output in Patients on Hemodialysis and Subjects Without Chronic Kidney Disease
      Bruno Lionardo de Paula, Bruno Valle Pinheiro, Eva Segura-Ortí, Fabrício Sciammarella Barros, Priscila Monteiro Veras, Kéller Soares Ávila, Leda Marília Fonseca Lucinda, Marco Antonio Cavalcanti Garcia, Maycon Moura Reboredo
      Journal of Renal Nutrition.2023; 33(4): 584.     CrossRef
    • Use of Isokinetic Dynamometry To Assess Muscle Function In Burned Patients Is A Reliable Tool To Assist Progressive Resistance Exercise Prescription
      Julianna M Dean, Andrew J Murton, Shauna Q Glover, Ileana Gutierrez, Clark R Andersen, David N Herndon, Jong O Lee, Oscar E Suman
      Journal of Burn Care & Research.2023; 44(3): 546.     CrossRef
    • Reliability and Validity of a Portable Traction Dynamometer in Knee-Strength Extension Tests: An Isometric Strength Assessment in Recreationally Active Men
      Danielle Garcia, Ivo Vieira de Sousa Neto, Yuri de Souza Monteiro, Denis Pinheiro Magalhães, Gleison Miguel Lissemerki Ferreira, Roberto Grisa, Jonato Prestes, Bruno Viana Rosa, Odilon Abrahin, Tatiane Meire Martins, Samuel Estevam Vidal, Rosimeire de Mou
      Healthcare.2023; 11(10): 1466.     CrossRef
    • Balance and Strength Measures are Associated With Mortality in Older Men
      Jack Paterson, Michelle Trevenen, Keith Hill, Osvaldo P. Almeida, Bu B. Yeap, Jonathan Golledge, Graeme J. Hankey, Leon Flicker
      Journal of the American Medical Directors Association.2023; 24(10): 1527.     CrossRef
    • Motor Strength Measurements Obtained Using an Inexpensive Spring Tensiometer and a Clinical Dynamometer Correlated Well: A Prospective Cohort Study
      Shizumasa Murata, Syed Tahmid, Omar Saad, Akihito Minamide, Hiroshi Yamada, S. Tim Yoon
      World Neurosurgery.2023; 179: e187.     CrossRef
    • Recovery of Lower Extremity Function in the Initial Year Following Periacetabular Osteotomy: A Single Subject Analysis
      Cailyn Schroeder, Linnea Zavala, Laura Opstedal, James Becker
      Physiotherapy Theory and Practice.2022; 38(9): 1233.     CrossRef
    • Meeting movement quantity or quality return to sport criteria is associated with reduced second ACL injury rate
      Nicky van Melick, Yvette Pronk, Maria Nijhuis‐van der Sanden, Sebastiaan Rutten, Tony van Tienen, Thomas Hoogeboom
      Journal of Orthopaedic Research.2022; 40(1): 117.     CrossRef
    • Isometric dynamometry, dependent on knee angle, is a suitable alternative to isokinetic dynamometry when evaluating quadriceps strength symmetry in patients following anterior cruciate ligament reconstruction
      Michael Beere, Jay R. Ebert, Brendan Joss, Timothy Ackland
      The Knee.2022; 34: 124.     CrossRef
    • Experimental Approach of Quadriceps Strength Measurement: Implications for Assessments in Critically Ill Survivors
      Anne-Françoise Rousseau, Isabelle Kellens, Pierre Delanaye, Olivier Bruyère, Benoit Misset, Jean-Louis Croisier
      Diagnostics.2022; 12(1): 202.     CrossRef
    • Handheld dynamometer reliability to measure knee extension strength in rehabilitation patients—A cross-sectional study
      João Pinto-Ramos, Tiago Moreira, Frederico Costa, Helena Tavares, João Cabral, Cristina Costa-Santos, Joana Barroso, Bernardo Sousa-Pinto, Shazlin Shaharudin
      PLOS ONE.2022; 17(5): e0268254.     CrossRef
    • The Association of the Medical Research Council Scale and Quantitative Computerized Dynamometry in Patients After Critical Illness: An Exploratory Study
      Anna Michalski, Leanna Souza-Barros, Priscila Robles, Jill Cameron, Margaret Herridge, Sunita Mathur
      Cardiopulmonary Physical Therapy Journal.2022;[Epub]     CrossRef
    • Feasibility of a preoperative strengthening exercise program on postoperative function in patients undergoing hip or knee arthroplasty: a pilot randomized controlled trial
      Lissa Pacheco-Brousseau, Johanna Dobransky, Alanna Jane, Paul E. Beaulé, Stéphane Poitras
      Pilot and Feasibility Studies.2022;[Epub]     CrossRef
    • Assessment of muscle strength in para-athletes: A systematic review of observational studies
      Seán R. O'Connor, Kristina Fagher, Samuel Williamson, Babette M. Pluim, Clare L. Ardern, Dina C. Janse van Rensburg, Neil Heron
      Sports Medicine and Health Science.2022; 4(4): 225.     CrossRef
    • Can Clinician-Stabilization with Hand-Held Dynamometry Yield a Reliable Measure of Knee Flexion Torque?
      Daniel Larson, Daniel Lorenz, Brittany Melton
      International Journal of Sports Physical Therapy.2022;[Epub]     CrossRef
    • Ön çapraz bağ rekonstrüksiyonu ile birlikte uygulanan artroskopik menisküs onarımının cerrahi sonrası rehabilitasyona etkileri
      Özge KASAPOĞLU, Rabia Tuğba KILIÇ, Hayri Baran YOSMAOĞLU
      Journal of Exercise Therapy and Rehabilitation.2022; 9(2): 83.     CrossRef
    • An experimental analysis of the sources of inaccuracy occurring in hip strength measurements conducted by hand held dynamometry
      Andrea Ancillao
      European Journal of Physiotherapy.2021; 23(2): 110.     CrossRef
    • The concurrent validity and intrarater reliability of a hand-held dynamometer for the assessment of neck strength in semi-professional rugby union players
      Adam Ashall, Nick Dobbin, Cari Thorpe
      Physical Therapy in Sport.2021; 49: 229.     CrossRef
    • Knee extensor strength, hop performance, patient-reported outcome and inter-test correlation in patients 9–12 months after anterior cruciate ligament reconstruction
      Jay R. Ebert, Peter Edwards, Luke Du Preez, Bonnie Furzer, Brendan Joss
      The Knee.2021; 30: 176.     CrossRef
    • Hand-Held Dynamometry in the Inpatient Care Setting After Total Knee Arthroplasty
      Musa Eymir, Ertugrul Yuksel, Bayram Unver, Vasfi Karatosun
      American Journal of Physical Medicine & Rehabilitation.2021; 100(6): 570.     CrossRef
    • The effect of transcranial direct stimulation as an add-on treatment to conventional physical therapy on pain intensity and functional ability in individuals with knee osteoarthritis: A randomized controlled trial
      Fatemeh Rahimi, Vahid Nejati, Gholamhossein Nassadj, Bahare Ziaei, Hossein Kouhzad Mohammadi
      Neurophysiologie Clinique.2021; 51(6): 507.     CrossRef
    • Kinesio Taping Relieves Pain and Improves Isokinetic Not Isometric Muscle Strength in Patients with Knee Osteoarthritis—A Systematic Review and Meta-Analysis
      Hsin-Yu Mao, Meng-Tzu Hu, Yea-Yin Yen, Shou-Jen Lan, Shin-Da Lee
      International Journal of Environmental Research and Public Health.2021; 18(19): 10440.     CrossRef
    • Reliability of stair-climbing speed in two cohorts of older adults
      Hanna Brodowski, Natascha Andres, Margareta Gumny, Cornelia Eicher, Elisabeth Steinhagen-Thiessen, Antje Tannen, Joern Kiselev
      International Journal of Therapy and Rehabilitation.2021; 28(11): 1.     CrossRef
    • Comparison of Common Methodologies for the Determination of Knee Flexor Muscle Strength
      Dan I Ogborn, Alix Bellemare, Brittany Bruinooge, Holly Brown, Sheila McRae, Jeff Leiter
      International Journal of Sports Physical Therapy.2021;[Epub]     CrossRef
    • Role of early short-term cardiac rehabilitation in patients undergoing pacemaker implantation
      Jinhee Ahn, Byeong Ju Lee, Seung-Young Roh, Bu Kyung Kim, Ji Yeon Kim, Laeun Kim, Kyung Tae Jang, Sun-Hack Lee, Jeong Cheon Choe, Jin Sup Park, Hye-Won Lee, Jun-Hyok Oh, Jung Hyun Choi, Han Cheol Lee, Kwang Soo Cha
      Reviews in Cardiovascular Medicine.2021;[Epub]     CrossRef
    • Concurrent validity of a fixated hand-held dynamometer for measuring isometric knee extension strength in adults with congenital heart disease
      Fredrik Nordin, André Nyberg, Camilla Sandberg
      European Journal of Physiotherapy.2020; 22(4): 206.     CrossRef
    • Routine monitoring of isometric knee extension strength in patients with muscle impairments using a new portable device: cross-validation against a standard isokinetic dynamometer
      Jean-Yves Hogrel, Olivier Benveniste, Damien Bachasson
      Physiological Measurement.2020; 41(1): 015003.     CrossRef
    • Validity and reliability of isometric knee extension muscle strength measurements using a belt-stabilized hand-held dynamometer: a comparison with the measurement using an isokinetic dynamometer in a sitting posture
      Masahiro Hirano, Munenori Katoh, Masahiro Gomi, Saori Arai
      Journal of Physical Therapy Science.2020; 32(2): 120.     CrossRef
    • The effect of Kinesio-tape® on pain and vertical jump performance in active individuals with patellar tendinopathy
      Kaori Tamura, Portia B. Resnick, Bruce P. Hamelin, Yukiya Oba, Ronald K. Hetzler, Christopher D. Stickley
      Journal of Bodywork and Movement Therapies.2020; 24(3): 9.     CrossRef
    • Moderate endurance and muscle training is beneficial and safe in patients with quiescent or mildly active Crohn’s disease
      Wolfgang Alexander Seeger, Juliane Thieringer, Philip Esters, Benjamin Allmendinger, Jürgen Stein, Hermann Schulze, Axel Dignass
      United European Gastroenterology Journal.2020; 8(7): 804.     CrossRef
    • Impact of Quadriceps/Hamstrings Torque Ratio on Three-Dimensional Pelvic Posture and Clinical Pubic Symphysis Pain-Preliminary Results in Healthy Young Male Athletes
      Oliver Ludwig, Jens Kelm, Sascha Hopp
      Applied Sciences.2020; 10(15): 5215.     CrossRef
    • Validity, Reliability, and Sensitivity to Change of DiCI for the Strength Measurement of Knee and Hip Muscles
      Rodrigo Martín-San Agustín, Josep C. Benítez-Martínez, Lorenzo Castillo-Ballesta, Mariano Gacto-Sánchez, Francesc Medina-Mirapeix
      Measurement in Physical Education and Exercise Science.2020; 24(4): 303.     CrossRef
    • Knee Extensor Strength Measurement in Patients With Limited Physical Activity Using a Supine Dynamometer Anchoring Frame
      Min-Yong Lee, Kwan-Sik Sung, Hyungsuk Ham, You Gyoung Yi, Hyung-Ik Shin
      Annals of Rehabilitation Medicine.2020; 44(6): 502.     CrossRef
    • New Device for Intrinsic Hand Muscle Strength Measurement: An Alternative to Strain Gauge Handheld Dynamometer
      Jagannathan Madhanagopal, Om Prakash Singh, Vikram Mohan, Kathiresan V. Sathasivam, Abdul Hafidz Omar, Mohammed Rafiq Abdul Kadir
      Evaluation & the Health Professions.2019; 42(1): 103.     CrossRef
    • Hand-held dynamometer identifies asymmetries in torque of the quadriceps muscle after anterior cruciate ligament reconstruction
      Gabriel Peixoto Leão Almeida, Thamyla Rocha Albano, Antônio Kayro Pereira Melo
      Knee Surgery, Sports Traumatology, Arthroscopy.2019; 27(8): 2494.     CrossRef
    • Different strength declines in leg primary movers versus stabilizers across age—Implications for the risk of falls in older adults?
      Franziska Daun, Armin Kibele, Riccardo Di Giminiani
      PLOS ONE.2019; 14(3): e0213361.     CrossRef
    • Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement
      Lidiane L. Florencio, Jaqueline Martins, Marcelo R.B. da Silva, Janaina R. da Silva, Gustavo L. Bellizzi, Débora Bevilaqua-Grossi
      Physical Therapy in Sport.2019; 38: 115.     CrossRef
    • The effects of intradialytic resistance training on muscle strength, psychological well-being, clinical outcomes and circulatory micro-ribonucleic acid profiles in haemodialysis patients
      Aurel Zelko, Ivana Skoumalova, Peter Kolarcik, Jaroslav Rosenberger, Miroslava Rabajdova, Maria Marekova, Andrea Madarasova Geckova, Jitse P. van Dijk, Sijmen A. Reijneveld
      Medicine.2019; 98(19): e15570.     CrossRef
    • Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position
      Kwan-Sik Sung, You Gyoung Yi, Hyung-Ik Shin
      BMC Musculoskeletal Disorders.2019;[Epub]     CrossRef
    • Early Post-Operative Intervention of Whole-Body Vibration in Patients After Total Knee Arthroplasty: A Pilot Study
      Yu-Hsuan Hsiao, Song-Hsiung Chien, Hung-Pin Tu, Jimmy Chun-Ming Fu, Shih-Ting Tsai, Ying-Shan Chen, Yi-Jen Chen, Chia-Hsin Chen
      Journal of Clinical Medicine.2019; 8(11): 1902.     CrossRef
    • The effect of patellar thickness on gait biomechanics following total knee arthroplasty
      Elizabeth A. Parke, Cass K. Nakasone, Samantha N. Andrews, Anne R. Wright, Christopher D. Stickley
      The Knee.2019; 26(6): 1354.     CrossRef
    • Modulation of Isometric Quadriceps Strength in Soccer Players With Transcranial Direct Current Stimulation: A Crossover Study
      Valentine Z. Vargas, Abrahão F. Baptista, Guilherme O.C. Pereira, Alberto C. Pochini, Benno Ejnisman, Marcelo B. Santos, Silvia M.A. João, Fuad A. Hazime
      Journal of Strength and Conditioning Research.2018; 32(5): 1336.     CrossRef
    • Effect of Squat Exercises on Lung Function in Elderly Women with Sarcopenia
      Yun Jeon, Myung Shin, Cheol Kim, Byeong-Ju Lee, Sang Kim, Da Chae, Jong-Hwan Park, Yong So, Hyuntae Park, Chang Lee, Byoung Kim, Jae Chang, Yong Shin, In Kim
      Journal of Clinical Medicine.2018; 7(7): 167.     CrossRef
    • Eccentric cross-exercise after anterior cruciate ligament reconstruction: Novel case series to enhance neuroplasticity
      Lindsey K. Lepley, Dustin R. Grooms, Julie P. Burland, Steven M. Davi, Jennifer L. Mosher, Marc L. Cormier, Adam S. Lepley
      Physical Therapy in Sport.2018; 34: 55.     CrossRef
    • Falls, muscle strength, and functional abilities in community-dwelling elderly women
      Viviane Santos Borges, Nayara Santos Silva, Ariana Cristina Malta, Nathália Cristina Xavier, Lorene Elka Santana Bernardes
      Fisioterapia em Movimento.2017; 30(2): 357.     CrossRef
    • Validation of Ankle Strength Measurements by Means of a Hand-Held Dynamometer in Adult Healthy Subjects
      Andrea Ancillao, Eduardo Palermo, Stefano Rossi
      Journal of Sensors.2017; 2017: 1.     CrossRef
    • Absolute reliability and concurrent validity of hand held dynamometry and isokinetic dynamometry in the hip, knee and ankle joint: systematic review and meta-analysis
      Claudio Chamorro, Susan Armijo-Olivo, Carlos De la Fuente, Javiera Fuentes, Luis Javier Chirosa
      Open Medicine.2017; 12(1): 359.     CrossRef
    • Reliability and Validity of the Belt-Stabilized Handheld Dynamometer in Hip- and Knee-Strength Tests
      Jaqueline Martins, Janaina Rodrigues da Silva, Marcelo Rodrigues Barbosa da Silva;, Débora Bevilaqua-Grossi
      Journal of Athletic Training.2017; 52(9): 809.     CrossRef
    • Reliability of muscle strength measures obtained with a hand‐held dynamometer in an elderly population
      Fanny Buckinx, Jean‐Louis Croisier, Jean‐Yves Reginster, Nadia Dardenne, Charlotte Beaudart, Justine Slomian, Sylvain Leonard, Olivier Bruyère
      Clinical Physiology and Functional Imaging.2017; 37(3): 332.     CrossRef
    • Analysis of Knee Strength Measurements Performed by a Hand-Held Multicomponent Dynamometer and Optoelectronic System
      Andrea Ancillao, Stefano Rossi, Paolo Cappa
      IEEE Transactions on Instrumentation and Measurement.2017; 66(1): 85.     CrossRef
    • Diagnostic Accuracy of Handheld Dynamometry and 1-Repetition-Maximum Tests for Identifying Meaningful Quadriceps Strength Asymmetries
      J. Anthony Sinacore, Andrew M. Evans, Brittany N. Lynch, Richard E. Joreitz, James J. Irrgang, Andrew D. Lynch
      Journal of Orthopaedic & Sports Physical Therapy.2017; 47(2): 97.     CrossRef
    • Clinical Predictors of Knee Mechanics at Return to Sport after ACL Reconstruction
      PAUL W. KLINE, DARREN L. JOHNSON, MARY LLOYD IRELAND, BRIAN NOEHREN
      Medicine & Science in Sports & Exercise.2016; 48(5): 790.     CrossRef
    • Robot-aided assessment of lower extremity functions: a review
      Serena Maggioni, Alejandro Melendez-Calderon, Edwin van Asseldonk, Verena Klamroth-Marganska, Lars Lünenburger, Robert Riener, Herman van der Kooij
      Journal of NeuroEngineering and Rehabilitation.2016;[Epub]     CrossRef
    • Immediate Effects of Kinesiology Taping of Quadriceps on Motor Performance after Muscle Fatigued Induction
      Ick Keun Ahn, You Lim Kim, Young-Hyeon Bae, Suk Min Lee
      Evidence-Based Complementary and Alternative Medicine.2015; 2015: 1.     CrossRef
    • Relationship Between Respiratory Muscle Strength and Conventional Sarcopenic Indices in Young Adults: A Preliminary Study
      Hee Joon Ro, Don-Kyu Kim, Sang Yoon Lee, Kyung Mook Seo, Si Hyun Kang, Hoon Chang Suh
      Annals of Rehabilitation Medicine.2015; 39(6): 880.     CrossRef

    Download Citation

    Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

    Format:

    Include:

    Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study
    Ann Rehabil Med. 2014;38(1):84-93.   Published online February 25, 2014
    Download Citation
    Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

    Format:
    • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
    • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
    Include:
    • Citation for the content below
    Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study
    Ann Rehabil Med. 2014;38(1):84-93.   Published online February 25, 2014
    Close

    Figure

    • 0
    • 1
    • 2
    • 3
    Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study
    Image Image Image Image
    Fig. 1 Flow chart represents a process of the study.
    Fig. 2 Study participant positioning for isokinetic dynamometer. (A) Sitting position and (B) supine position.
    Fig. 3 Study participant positioning for fixed and non-fixed HHD methods. (A) Fixed HHD method with sitting and supine position was observed. (B) Non-fixed HHD method with sitting and supine position was observed.
    Fig. 4 Correlation of fixed HHD and non-fixed HHD methods (x-axis) with isokinetic dynamometer (y-axis) in a scatter diagram. HHD, hand-held dynamometer; Rt., right; Lt., left. *p<0.05 was considered significant.
    Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

    Descriptive statistics of fixed and non-fixed HHD isokinetic dynamometer (unit, Nm)

    HHD, hand-held dynamometer; Rt., right; Lt., left; SD, standard deviation.

    a)p<0.05 difference between the result of supine position and seat position. b)p<0.05 difference between the result of isokinetic dynamometer and non-fixed HHD. c)p<0.05 difference between the result of fixed HHD and non-fixed HHD.

    Pearson correlation coefficient (r) between fixed HHD and non-fixed HHD methods according to isokinetic dynamometer

    HHD, hand-held dynamometer; Rt., right; Lt., left.

    *p<0.05 was considered significant.

    ICC and SEM of fixed HHD and non-fixed HHD methods by three testers

    HHD, hand-held dynamometer; ICC, intraclass correlation coefficient; SEM, standard error of measurement; Rt., right; Lt., left.

    Intra-rater reliability of fixed HHD method

    HHD, hand-held dynamometer; ICC, intraclass correlation coefficient; SEM, standard error of measurement; Rt., right; Lt., left.

    Table 1 Descriptive statistics of fixed and non-fixed HHD isokinetic dynamometer (unit, Nm)

    HHD, hand-held dynamometer; Rt., right; Lt., left; SD, standard deviation.

    a)p<0.05 difference between the result of supine position and seat position. b)p<0.05 difference between the result of isokinetic dynamometer and non-fixed HHD. c)p<0.05 difference between the result of fixed HHD and non-fixed HHD.

    Table 2 Pearson correlation coefficient (r) between fixed HHD and non-fixed HHD methods according to isokinetic dynamometer

    HHD, hand-held dynamometer; Rt., right; Lt., left.

    *p<0.05 was considered significant.

    Table 3 ICC and SEM of fixed HHD and non-fixed HHD methods by three testers

    HHD, hand-held dynamometer; ICC, intraclass correlation coefficient; SEM, standard error of measurement; Rt., right; Lt., left.

    Table 4 Intra-rater reliability of fixed HHD method

    HHD, hand-held dynamometer; ICC, intraclass correlation coefficient; SEM, standard error of measurement; Rt., right; Lt., left.

    TOP