This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
To clarify the influence of recording electrode placement on F-wave parameters, we investigated F-wave parameters recorded from the abductor pollicis brevis muscle using different recording electrode positions.
Methods
Thirteen healthy volunteers participated. Recording electrodes were placed at four locations (20, 30, 40, and 50 mm from the reference electrode). The stimulating electrode was positioned over the median nerve at the wrist, and the reference electrode was placed on the distal tendon of the abductor pollicis brevis muscle. Stimulation intensity was set at 1.2 times that required to elicit the maximal M-wave amplitude. Thirty stimuli were delivered at 0.5 Hz. Outcome measures included M-wave latency and amplitude, F-wave mean latency and amplitude, F/M amplitude ratio, and F-wave persistence. Data were analyzed using one-way repeated-measures analysis of variance, and effect sizes were calculated using partial η².
Results
M-wave amplitude varied substantially according to recording electrode position (partial η²=0.50). In contrast, effect sizes were small for most F-wave parameters. The F/M amplitude ratio did not reach statistical significance but demonstrated a moderate-to-large effect size (partial η²=0.24).
Conclusion
Recording electrode placement substantially affected M-wave amplitude and may also influence the F/M amplitude ratio. Therefore, consistent electrode placement should be maintained when interpreting these parameters in clinical or research settings. However, given the relatively small sample size, clinically meaningful effects on other F-wave parameters cannot be excluded and should be investigated in larger studies.
F-waves are compound muscle action potentials elicited by antidromic activation of alpha motor neuron axons and subsequent backfiring of anterior horn cells in response to electrical stimulation. Several F-wave parameters are used to assess the state of alpha motor neurons: F-wave latency reflects nerve conduction velocity, F-wave persistence indicates the excitability of the alpha motor neuron pool, and the F/M amplitude ratio represents the relative size of the backfiring motor units [1]. Accordingly, F-waves are widely used for the diagnosis and evaluation of various neuromuscular disorders.
F-wave latency is highly reproducible and is commonly used to diagnose diabetic neuropathy and other neurological conditions [2,3]. In contrast, F-wave amplitude and F-wave persistence are relatively less reliable and may have limited diagnostic value. One factor contributing to this variability is the mechanism underlying F-wave generation; because different motor units are activated with each stimulus, both F-wave amplitude and F-wave persistence tend to fluctuate. In addition, variations in electrode placement caused by differences among examiners or examination sessions may further contribute to measurement variability.
The belly–tendon method, in which the recording electrode is placed over the muscle belly and the reference electrode over the tendon, is commonly used for F-wave recordings. However, no standardized guidelines exist regarding precise electrode placement. Although previous studies have examined the influence of reference electrode placement on F-wave recordings, the effect of recording electrode position remains unclear [4]. Previous studies have reported that changes in recording electrode position significantly affect M-wave amplitude [5-7]. Therefore, we hypothesized that the position of the recording electrode during F-wave recording might also influence F-wave parameters.
F-waves are frequently recorded from the abductor pollicis brevis, abductor digiti minimi, and abductor hallucis muscles following stimulation of the median, ulnar, or tibial nerves [8]. Among these, F-waves recorded from the abductor pollicis brevis muscle are most commonly used for clinical diagnosis and research purposes [9,10]. Accordingly, this study investigated the effects of recording electrode placement on F-wave parameters obtained from the abductor pollicis brevis muscle. We hypothesized that the F-wave mean amplitude would vary depending on electrode placement.
METHODS
Participants
Thirteen healthy participants (6 males and 7 females; mean age 32.1±12.7 years; mean height 167.3±8.1 cm; mean weight 59.4±8.4 kg) were included in this study. Participants were recruited from a local college. Individuals in good general health were included, whereas those with a history or presence of neurological or orthopedic diseases were excluded.
Experimental design
Recording electrodes were placed along a line over the abductor pollicis brevis muscle at distances of 20, 30, 40, and 50 mm from the reference electrode (Fig. 1). F-waves were recorded sequentially at each electrode position.
The order of the trials was randomized using a computer-generated random sequence. A minimum rest interval of 5 minutes was provided between trials.
F-wave recording
F-waves were recorded using a Viking Quest system, version 7.5 (Nicolet Biomedical Inc.). Cup electrodes with a diameter of 10 mm were used as the recording and reference electrodes, and a plate electrode with a diameter of 30 mm served as the ground electrode. A bipolar bar electrode with 9-mm gold plate discs was used for stimulation.
Before electrode placement, the skin was cleaned with alcohol and gently abraded using an abrasive cream. The stimulating electrode was applied over the median nerve at the wrist and secured with a bandage. The cathode position was adjusted to elicit the largest M-wave amplitude using low-intensity stimulation. The recording electrode was attached at each of the four predefined locations over the abductor pollicis brevis muscle. The reference electrode was placed slightly proximal to the base of the first phalanx, over the tendon region of the abductor pollicis brevis muscle. The ground electrode was placed on the palmar surface of the mid-forearm.
Electrical stimulation of the median nerve was delivered at an intensity of 1.2 times that required to elicit a maximal M-wave. The stimulus duration was 0.2 ms, the stimulation frequency was 0.5 Hz, and 30 stimuli were delivered for each condition. The band-pass filter was set between 20 Hz and 3,000 Hz. During recordings, participants lay supine and were instructed to remain relaxed with their eyes open. Room temperature was maintained at 25°C to minimize the influence of temperature on nerve conduction velocity.
Data analysis
Viking Quest version 7.5 did not provide a baseline correction function for F-waves, and F-wave amplitude could be underestimated because of baseline distortion caused by the M-wave tail. Therefore, waveform data were transferred to Viking Quest version 20.0 (Natus Medical Inc.), and baseline correction was performed using the “Signal Enhancer” function. An examiner blinded to the trial order analyzed all M- and F-wave recordings.
M-wave latency was defined as the onset latency of the M-wave evoked by the first stimulus of each trial. M-wave amplitude was defined as the peak-to-peak amplitude of the M-wave evoked by the first stimulus. Based on previous studies [11-13], an F-wave was defined as any response occurring after the M-wave with an amplitude greater than 30 μV. The F-wave mean amplitude was calculated as the average peak-to-peak amplitude of all identified F-waves. F-wave persistence was calculated as the number of F-waves divided by the total number of stimuli and expressed as a percentage. The F/M amplitude ratio was calculated as the ratio of the F-wave mean amplitude to the M-wave amplitude and expressed as a percentage.
Statistical analysis
Statistical analyses were performed using IBM SPSS Statistics for Windows, version 20.0 (IBM Corp.). Normality of the data was assessed using the Shapiro–Wilk test, and sphericity was evaluated using Mauchly’s test. When sphericity was violated, the Greenhouse–Geisser correction was applied. Differences among electrode positions were analyzed using a one-way repeated-measures analysis of variance. Effect size was calculated using partial eta squared (η²). Post hoc comparisons were performed using paired t-tests with Bonferroni correction. A p-value<0.05 was considered statistically significant.
Ethics statement
All participants provided written informed consent. This study was approved by the Kobe College of Rehabilitation and Health Ethics Review Committee (approval No. 2201).
RESULTS
The results for each parameter are presented in Table 1. According to the one-way repeated-measures ANOVA, no significant differences were observed in M-wave latency (p=0.08, partial η²=0.17). Mauchly’s test indicated a violation of sphericity for M-wave amplitude (p<0.05). After applying the Greenhouse–Geisser correction, the one-way repeated-measures ANOVA revealed a significant difference (p<0.01, partial η²=0.50). Post hoc comparisons showed that M-wave amplitude was significantly higher in the 30 mm trial than in the 20 and 50 mm trials (p<0.05 for both). Furthermore, M-wave amplitude in the 40 mm trial was significantly greater than that in the 50 mm trial (p<0.05).
No significant differences were observed in F-wave mean latency (p=0.16, partial η²=0.13), F-wave mean amplitude (p=0.44, partial η²=0.07), or F-wave persistence (p=0.72, partial η²=0.12) according to the one-way repeated-measures ANOVA. For the F/M amplitude ratio, Mauchly’s test indicated a violation of sphericity (p<0.05). After applying the Greenhouse–Geisser correction, the one-way repeated-measures ANOVA showed no significant difference (p=0.053, partial η²=0.24). However, the large effect size may suggest a potential influence of electrode placement.
DISCUSSION
This study investigated the effects of changes in recording electrode placement on M-wave and F-wave parameters. M-wave amplitude varied significantly according to electrode position. We hypothesized that the F-wave mean amplitude would also vary depending on electrode placement. However, no statistically significant differences were detected in F-wave mean amplitude, F-wave mean latency, or F-wave persistence across electrode positions. Nevertheless, the F/M amplitude ratio approached statistical significance (p=0.05) and showed a medium-to-large effect size (partial η²=0.24). Given the relatively small sample size of the present study, the absence of statistically significant differences in most F-wave parameters should not be interpreted as evidence of no effect, and clinically meaningful effects cannot be excluded. To the best of our knowledge, this is the first study to examine the influence of recording electrode placement on F-wave parameters.
When the recording electrode was positioned 30 mm from the reference electrode, the M-wave amplitude was at its maximum. This result supports previous research, which showed that placing the recording electrode at the center of the abductor pollicis brevis muscle increases M-wave amplitude compared with positions located proximally or distally [5]. The point where the motor nerve contacts the muscle is known as the neuromuscular junction, and the area where these junctions are concentrated is termed the innervation zone. Studies using array electrodes have reported the width of the innervation zone for the thenar muscles to be approximately 20 mm [14]. Stimulating the motor nerve generates numerous single motor unit potentials within the innervation zone. These produce a negative potential centrally and positive potential laterally. Therefore, when the recording electrode is placed over the innervation zone, a large negative compound muscle action potential is initially recorded. Subsequently, as motor unit potentials propagate toward both ends of the muscle, positive potentials are recorded, and the M-wave assumes a gradually undulating shape. In this study, the M-wave amplitude was maximal at the 30 mm location, suggesting that the innervation zone was located near this area. The decrease in M-wave amplitude at the 20 and 50 mm positions is likely attributable to phase cancellation. Muscle fiber diameter correlates with muscle fiber conduction velocity, and fibers of different diameters coexist within a single muscle [15]. As the distance between the recording electrode and the innervation zone increases, temporal dispersion between fast- and slow-conducting motor unit potential also increases. This likely enhances phase cancellation among single motor unit potentials and reduces the recorded M-wave amplitude.
Similar to the M-wave, the F-wave is a volume-conducted potential and may therefore be influenced by recording electrode placement. However, unlike the M-wave, which is composed of the summated activity of numerous motor unit action potentials and is therefore susceptible to phase cancellation, the F-wave consists of substantially fewer motor unit action potentials. In the present study, the F/M amplitude ratio was approximately 1%–2%, indicating that the F-wave was generated by considerably fewer motor units than the M-wave. Furthermore, F-wave responses exhibit variability in latency. Consequently, even when the recording electrode is positioned away from the innervation zone, phase cancellation is less likely to occur than for the M-wave. These physiological characteristics may explain why recording electrode placement had a relatively small effect on F-wave mean amplitude compared with M-wave amplitude. As a result, M-wave amplitude varied significantly across electrode positions, whereas F-wave mean amplitude showed only a small-to-medium effect size (partial η²=0.07). The medium-to-large effect size observed for the F/M amplitude ratio (partial η²=0.24) may therefore reflect the combination of a substantial change in M-wave amplitude and a relatively small change in F-wave amplitude.
M-wave latency reflects the earliest muscle action potential. As reported in previous studies, the intramuscular distribution of motor nerve branches within the abductor pollicis brevis is anatomically complex [16]. The tendency for the shortest M-wave latency to be observed at an electrode position of approximately 40 mm may suggest that, although the putative innervation zone was located around 30 mm, some motor nerve branches supplying the muscle fibers beneath the 40 mm electrode position had relatively short conduction paths. However, the present study was not designed to determine the exact branching pattern of these motor nerves. Compared with M-wave latency, F-wave latency showed slightly less variation across recording electrode positions (effect size: 0.17 vs. 0.13). Because F-wave latency varies from stimulus to stimulus, the inherent variability in F-wave generation may have masked small latency differences attributable to electrode placement.
This study suggests that changes in recording electrode placement result in significant alterations in M-wave amplitude and may also influence the F/M amplitude ratio. Therefore, consistent electrode placement is recommended, particularly when M-wave amplitude or the F/M amplitude ratio is used as an outcome measure. This study has several limitations. First, only healthy volunteers were included; therefore, the findings may not be generalizable to patient populations with altered nerve conduction properties, such as those with diabetic polyneuropathy. Future studies involving such populations are needed to further validate the present findings. Second, although electrode spacing was standardized using four predefined locations, inter-individual differences in body size may have influenced the spatial relationship between the electrodes and the innervation zone. Additionally, no a priori power analysis was conducted to determine the sample size, which limits the ability to assess whether the study was adequately powered. Given the relatively small sample size (N=13), particularly in a repeated-measures design with multiple conditions, the possibility of Type II error cannot be excluded. Therefore, the present findings should be interpreted as exploratory, and further validation with larger samples is warranted.
Conclusion
Recording electrode placement significantly affected M-wave amplitude. For most F-wave parameters, no statistically significant differences were detected; however, the relatively small sample size and observed effect sizes mean that clinically meaningful effects cannot be excluded. In particular, the F/M amplitude ratio approached statistical significance and demonstrated a moderate-to-large effect size, suggesting that electrode placement may influence this parameter. Therefore, consistent electrode placement should be maintained, particularly when M-wave amplitude or the F/M amplitude ratio is used in clinical or research settings.
CONFLICTS OF INTEREST
No potential conflict of interest relevant to this article was reported.
FUNDING INFORMATION
None.
AUTHOR CONTRIBUTION
Conceptualization: Kurobe M. Data curation: Kurobe M. Formal analysis: Kurobe M. Investigation: Kurobe M. Methodology: Kurobe M, Kado N. Project administration: Suzuki T. Supervision: Suzuki T. Visualization: Kurobe M. Writing – original draft: Kurobe M. Writing – review & editing: Kado N, Suzuki T. Approval of final manuscript: all authors.
ACKNOWLEDGMENTS
We are grateful to the volunteers for participating in this study.
Fig. 1.
The position of the reference and recording electrodes. The reference electrode (gray circle) was attached slightly proximal to the base of the first phalanx, over the tendon region of the abductor pollicis brevis muscle. The recording electrodes (white circles) were attached along a line over the abductor pollicis brevis muscle, at distances of 20, 30, 40, and 50 mm from the reference electrode.
3. Kohara N, Kimura J, Kaji R, Goto Y, Ishii J, Takiguchi M, et al. F-wave latency serves as the most reproducible measure in nerve conduction studies of diabetic polyneuropathy: multicentre analysis in healthy subjects and patients with diabetic polyneuropathy. Diabetologia 2000;43:915-21.
4. Takahashi N, Otsuka T, Okahashi S, Takahashi O, Takahashi M. The influence of the reference electrode in recording F-waves. Electromyogr Clin Neurophysiol 2007;47:279-83.
5. van Dijk JG, van der Kamp W, van Hilten BJ, van Someren P. Influence of recording site on CMAP amplitude on its variation over a length of nerve. Muscle Nerve 1994;17:1286-92.
6. van Dijk JG, van Benten I, Kramer CG, Stegeman DF. CMAP amplitude cartography of muscles innervated by the median, ulnar, peroneal, and tibial nerves. Muscle Nerve 1999;22:378-89.
15. Hakansson CH. Conduction velocity and amplitude of the action potential as related to circumference in the isolated fibre of frog muscle. Acta Physiol Scand 1956;37:14-34.
16. Xie P, Jiang Y, Zhang X, Yang S. The study of intramuscular nerve distribution patterns and relative spindle abundance of the thenar and hypothenar muscles in human hand. PLoS One 2012;7:e51538.
M-Wave and F-Wave Parameters in Relation to Recording Electrode Placement
Fig. 1. The position of the reference and recording electrodes. The reference electrode (gray circle) was attached slightly proximal to the base of the first phalanx, over the tendon region of the abductor pollicis brevis muscle. The recording electrodes (white circles) were attached along a line over the abductor pollicis brevis muscle, at distances of 20, 30, 40, and 50 mm from the reference electrode.
Graphical abstract
Fig. 1.
Graphical abstract
M-Wave and F-Wave Parameters in Relation to Recording Electrode Placement