Ultrasonographic Analysis of Optimal Needle Placement for Extensor Indicis
Article information
Abstract
Objective
To determine the most optimal needle insertion point of extensor indicis (EI) using ultrasound.
Methods
A total 80 forearms of 40 healthy volunteers were recruited. We identified midpoint (MP) of EI using ultrasound and set MP as optimal needle insertion point. The location of MP was suggested using distances from landmarks. Distance from MP to medial border of ulna (MP-X) and to lower margin of ulnar head (MP-Y) were measured. Ratios of MP-X to Forearm circumference (X ratio) and MP-Y to forearm length (Y ratio) were calculated. In cross-sectional view, depth of MP (Dmp), defined as middle value of superficial depth (Ds) and deep depth (Dd) was measured and suggested as proper depth of needle insertion.
Results
Mean MP-X was 1.37±0.14 cm and mean MP-Y was 5.50±0.46 cm. Mean X ratio was 8.10±0.53 and mean Y ratio was 22.15±0.47. Mean Dmp was 7.63±0.96 mm.
Conclusion
We suggested that novel optimal needle insertion point of the EI. It is about 7.6 mm in depth at about 22% of the forearm length proximal from the lower margin of the ulnar head and about 8.1% of the forearm circumference radial from medial border of ulna.
INTRODUCTION
The extensor indicis (EI) muscle arises from the posterior surface of the distal third of the ulna and the adjacent interosseous membrane [1]. It proceeds diagonally, turning into the tendon and inserting into the index finger via the extensor expansion [2,3]. The muscle belongs to the deep layer of the posterior compartment of the forearm [4], located under the extensor digitorum and extensor digiti minimi muscles [5]. It is innervated by the posterior interosseous nerve, which is a branch of the radial nerve, and receives its blood supply from the posterior interosseous artery [4,6].
The EI is used clinically for diagnosis and treatment of several diseases. In needle electromyography (EMG), the EI is important for diagnosis of radial nerve or C7 and C8 nerve root lesions. The EI is also used as electrode attachment site for the compound muscle action potentials of the radial nerve in nerve conduction studies. The EI is a target muscle for botulinum toxin injection in patients with hand dystonia or post-stroke spasticity of the upper extremities [7,8]. Trigger point injection of the EI is often performed in patients with myofascial syndrome caused predominantly by finger overuse [9].
An optimal needle insertion position for EI has been suggested by several EMG methods [10-12]. However, the needle insertion positions of these methods differ from each other. Because the EI is thin and covered by the superficial layer muscles of the forearm [4], it is difficult to precisely insert a needle into the EI. Several previous studies showed that the accuracy of needle insertion into the EI is low [13,14]. Im et al. [2] attempted to identify the optimal needle insertion point for the EI in cadavers. However, the proper depth of needle placement was not discussed. Also, there was a limitation in that living musculoskeletal structures may differ from those in cadavers. Aside from the cadaveric study, there have not been any studies on optimal needle placement in the EI in living human bodies.
The purpose of this study is to determine the optimal needle insertion point considering the anatomical location of the EI with surrounding structures using ultrasound.
MATERIALS AND METHODS
Study design
This was a cross-sectional study that investigated the proper needle insertion point in the EI using ultrasound.
Subjects
Forty healthy volunteers were recruited for this study. Both forearms were measured in all subjects, so a total of 80 forearms were examined. Upper extremity amputation patients and subjects who had a cast, splint, or artifact-producing metal fixture in the forearm were excluded. Persons with previous surgery on the forearm were also excluded, because the operation might cause structural changes in the forearm muscles. Demographic characteristics, including age, sex, height, weight, and body mass index (BMI), were collected.
All participants received a comprehensive explanation of the study and signed an informed consent form. The present study was approved by the Institutional Review Board of Soonchunhyang University Buchoen Hospital (No. 2019-10-002-001).
Ultrasonographic examination
All subjects underwent ultrasonographic evaluation in the supine position with the forearm fully pronated, the elbow flexed about 30°, and the shoulder abducted about 30°. Before ultrasonographic evaluation, wrist circumference and forearm length were measured in this position. Forearm length was defined as the vertical distance from the elbow crease to the lower margin of the ulnar head. Wrist circumference was measured at the level of the lower margin of the ulnar head.
After measurements were taken, ultrasonographic evaluation was performed by a physiatrist with more than 5 years of experience with musculoskeletal ultrasound, using a XARIO (SSA-660A; Toshiba, Minato, Japan) with a 7–18 MHz linear array transducer (Toshiba). Because the EI shows a fusiform-shaped muscle belly [15], the midpoint of the EI (MP), which can easily be identified and targeted, was suggested as an optimal needle insertion point in this study. The vertical location of MP was defined as the point midway between the proximal origin (PO) and the musculotendinous junction (MTJ) of the EI. To determine the location of MP, the PO and MTJ of the EI were first identified on short-axis view by moving a probe proximally from the lower margin of the ulnar head. The locations of the PO and MTJ on shortaxis view were confirmed on long-axis view. The PO and MTJ were marked on the skin, as shown in Fig. 1A. MP was investigated by moving the probe horizontally midway between the PO and MTJ. The point where the EI was located on the midline on short-axis view was set as MP. MP was also marked on the skin and forearm circumference at the level of MP was measured. To represent MP location, the medial border of the ulna was set as a landmark of horizontal distance and the lower margin of the ulnar head was used as a landmark of vertical distance. The distances from MP to the medial border of the ulna (MP-X) and to the lower margin of the ulnar head (MP-Y) were measured (Fig. 1A). In order to indicate MP position relative to forearm circumference and length, the ratios of MP-X to forearm circumference (X ratio) and MP-Y to forearm length (Y ratio) were calculated as percentages. Using these measurements, the distances and ratios of MP were obtained. On a cross-sectional view of MP (Fig. 1B), the superficial depth (Ds) and deep depth (Dd) of the EI were measured. The depth of MP (Dmp) was defined as the median value of the Ds and Dd and suggested as the optimal depth for needle insertion.
There are several existing needle insertion methods based on EMG. Perotto et al. [10] suggested needle insertion at two finger breadths proximal to the ulnar styloid process, just radial to the ulna at a depth of one-half inch (Point A). Lee and DeLisa [11] recommended inserting the needle in the distal fourth of the forearm lateral to the radial side of the ulna between the extensor digitorum and extensor carpi ulnaris tendons (Point B). ChuAndrews and Johnson [12] proposed needle insertion at 2.5 cm proximal to the lower border of the styloid process of the ulna, in line with the lateral aspect of the ulna with the forearm pronated (Point C). Needle location and muscle penetration using these methods were analyzed in this study. With the three existing needle EMG methods, each needle insertion point is marked on the skin. On cross-sectional view at each point (Fig. 2), using an imaginary needle pathway, whether the needle can be inserted in the EI, the needle location in the EI if insertion is possible, and the other muscles that could be involved were investigated. Needle location in the EI was classified into the middle portion or the other portion. The middle portion of the EI is defined as the middle third when the muscle is divided into three parts. Needle insertion in the EI or other muscles were recorded. The distances from each insertion point to MP in the three different methods were also measured.
In order to accurately distinguish between different muscles, ultrasound was performed while contraction of surrounding muscles, such as the EI, extensor digitorum, extensor digiti minimi, and extensor pollicis longus was induced. During ultrasound examination, the probe was held perpendicular to the muscle with minimal pressure to ensure accurate measurement.
Statistical analysis
Anatomical and ultrasound parameters and demographic data are represented as mean±standard deviation. Normality of data distribution was confirmed using the Shapiro-Wilk test. ANOVA and Student t-test were used to compare parameters between groups. Bonferroni post-hoc test was performed to identify the differences in MP-X and MP-Y between the groups. To compare the accuracy of each EMG method between height groups, the chi-square test was conducted. A p-value of 0.05 or less was determined to be statistically significant. All analyses were executed using SPSS software ver. 19.0 (IBM, Armonk, NY, USA).
RESULTS
A total of 80 forearms of 40 participants (20 men and 20 women) were examined. The mean age was 30.7±6.8 years and the mean height was 168.9±10.8 cm. Detailed demographic data are presented in Table 1.
Anatomical and sonographic measurements are summarized in Table 2. Mean forearm length was 24.83±2.12 cm and forearm circumference at MP was 16.96±1.67 cm. The MP-Y was 5.50±0.46 cm and the mean Y ratio was 22.15±0.47. The MP-X was 1.37±0.14 cm and the mean X ratio was 8.10±0.53. The Ds and Dd of the EI at MP were 4.40±0.97 mm and 10.85±1.31 mm, respectively, and Dmp was 7.63±0.96 mm. There were significant differences in forearm length, forearm circumference, MP-Y, MP-X, Ds, and Dd between men and women. However, the Y ratio, X ratio, and Dmp did not significantly differ between the sexes. There were no significant differences between the right and left sides in any measurements.
The participants were categorized into four groups according to height. MP-Y, Y ratio, MP-X, and X ratio of each group are shown in Table 3. MP-Y and MP-X showed a tendency to increase as height increased, whereas the Y ratio and X ratio did not. The Y ratio and X ratio did not show statistically significant differences between groups. However, MP-Y and MP-X significantly differed between groups.
Post-hoc tests revealed no significant differences in MP-X between the 150s and 160s groups (p=0.105), 160s and 170s groups (p=0.063), and 170s and 180s groups (p=0.558). On the other hand, there were significant differences in MP-X between the 150s and 170s groups (p<0.0001), 150s and 180s groups (p<0.0001), and 160s and 180s groups (p=0.001). In post-hoc analysis of MP-Y, significant differences were identified between all groups (150 vs. 160, p=0.007; others, p<0.0001).
The structures into which the needle could be inserted according to the three EMG methods are shown in Table 4. Short-axis ultrasound images of points on the skin taken using the three methods are shown in Fig. 2. The probability that the needle course passes the EI was 100%, 50%, and 100% and the probability that the needle crosses the middle portion of the EI was 52.5%, 16.25%, and 42.5% for points A, B, and C, respectively. In these three points, the needle had to penetrate other muscles in 100% of cases in order for the needle to reach the EI. The most often penetrated muscle was the extensor digiti minimi in all three methods. The mean distances between MP and each point on the skin were 2.43±0.65 cm, 1.20±0.37 cm and 3.34±0.71 cm. Point B was closest and point C was farthest away (Table 4). For each method, the differences in accuracy of needle placement between height groups were analyzed. Needle placement was divided depending on whether the needle passed through the middle portion of the EI, other portion of the EI, or not at all. In all methods, there were no significant between-group differences (point A, p=0.809; point B, p=0.109; point C, p=0.450).
DISCUSSION
In this study, a new needle insertion method for the EI using ultrasound is proposed. We demonstrated that the MP of the EI was located on average about 5.5 cm proximal from the lower margin of the ulnar head and about 1.4 cm radial from the medial border of the ulna. We also identified that if a needle is inserted about 7.6 mm deep at about 22% of the forearm length from the lower margin of the ulnar head and about 8.1% of the forearm circumference from the medial border of the ulna, it will be placed in MP of the EI. Studies have been done on the optimal location of needle insertion in various muscles based on ultrasound, but to the best of our knowledge, this is the first study to investigate needle insertion position in the EI using ultrasound.
The EI is used for diagnosis of several neurologic lesions in needle EMG and treatment of spasticity or myofascial syndrome using botulinum toxin injection or trigger point injection. If the needle is placed incorrectly, a misdiagnosis can be made or the therapeutic effect may be diminished. For example, unintended muscle weakness can occur after botulinum toxin injection due to inaccurate needle insertion. Nevertheless, needle EMG or injection is usually performed blindly in practice because using ultrasound or computed tomography to ensure needle placement requires a large investment in time and cost. Therefore, it is very important to establish a method for precise needle insertion into the EI that is applicable to patients in general.
Accurate needle insertion in the EI is challenging. There are several reasons why it is so difficult. First, the EI is thin and runs diagonally [2]. Thus, even a slight change in needle position may result in incorrect needle insertion. As the EI runs distally, it becomes a tendon and the thickness of the belly decreases, which makes it difficult to place the needle in this muscle when insertion is in the distal part. If the needle is inserted too radially or proximally, it may end up in the abductor pollicis longus or extensor pollicis longus [10,11]. Needle insertion distal to the EI may lead to positioning in the tendon of the EI [2]. Second, the EI is covered by superficial muscles of the forearm and is not prominent because of its small size. Muscles in the posterior compartment of the forearm can be divided into a superficial layer and a deep layer. The superficial layer includes the brachioradialis, extensor carpi radialis longus, extensor carpi radialis brevis, extensor carpi ulnaris, anconeus, extensor digitorum, and extensor digiti minimi, whereas the deep layer includes the extensor indicis, abductor pollicis longus, extensor pollicis longus, extensor pollicis brevis, and supinator [4]. The EI is positioned under superficial layer muscles such as the extensor digiti minimi and extensor digitorum communis and does not protrude anatomically, unlike the thenar or hypothenar muscles. Therefore, it is difficult to insert a needle after confirming the contour of the muscle through palpation. Previous studies on the accuracy of blind needle insertion for muscles in the extremities have shown that deep muscles are associated with lower insertion accuracy compared to superficial muscles, and smaller muscles have lower insertion accuracy than larger muscles [13]. The needle can be placed in the extensor digiti minimi or extensor carpi ulnaris after superficial insertion or the pronator quadratus after deep insertion [13,16]. Third, because the EI is not clearly separated from other muscles that are innervated by the radial nerve, it is difficult to distinguish the EI from other muscles [17]. Due to the characteristics of the EI, a muscle contraction is often induced to identify the location of the muscle and insert the needle exactly. However, a large number of patients with radial neuropathy, who commonly undergo needle EMG, show decreased muscle strength in the index finger. So, it is difficult to palpate the EI using muscle contraction in these patients. Since patients with post-stroke spasticity have difficulty with selective finger movement, co-contraction of the forearm muscles hinders the effort to identify the location of the EI [18].
Previous studies showed that correct needle insertion in the EI is not easy. Karvelas et al. [14] investigated the accuracy of needle EMG of the EI, pronator teres, peroneus longus, and soleus when third- and fourth-year medical residents performed needle EMG in live subjects. The accuracy of insertion into the EI was 20%–42%, which was the lowest value among the examined muscles. In a cadaveric study, Goodmurphy et al. [13] proved that the EI, serratus anterior, flexor carpi ulnaris, and flexor carpi radialis were the most difficult to properly insert a needle into among the muscles of the upper extremities.
Several needle EMG methods for the EI have been proposed. The probability that the needle pathway passes through the EI was 100% at points A and C. However, the probability of passing the middle portion was not high, at just 52.5% and 42.5%, respectively. Because simply piercing the muscle does not imply correct needle placement in the EI and the belly is thinner in the distal portion, the accuracy of needle insertion methods performed at the distal portion, such as points A and C, may be lower than 100%. Finger breadth is used as a measurement tool in point A, but this is not an objective tool because it differs between examiners. Point C uses an objective value of 2.5 cm, which is difficult to apply to everyone because each person has a different forearm length. Point B was closest to the MP, but showed the lowest probability of the needle pathway crossing the EI or crossing the middle portion of the EI among the three methods (50% and 16.25%, respectively). In the remaining 50% of cases, in which the needle did not pass the EI, the needle pathway pierced the extensor pollicis longus, which is located directly radial to the EI. Therefore, the low accuracy at point B may be because the needle is not inserted into the EI even if the transverse position is slightly altered due to the elongated shape of the EI.
The mean distance from MP to each of the skin points is presented in this study (Table 4). These points were located in different directions from MP. Points A and C were distal and radial from MP. The needle pathways at points A and C penetrated the EI in all cases. Therefore, the depth is more important than the horizontal and vertical distances when inserting the needle at points A and C. Unlike points A and C, point B was located proximally and radially from MP. The needle pathway at point B passed through the EI in only 50% of cases. In the 50% of cases in which the needle did not pass through the EI, the needle pathway penetrated the extensor pollicis longus, which is located on the radial side of the EI. If the needle is not positioned correctly in the EI at point B, the needle should be repositioned toward the ulnar side.
MP presented in this study has several advantages over previous methods. At points A, B, and C, the needle could reach the EI only by penetrating the superficial layer muscles, extensor digiti minimi, or extensor digitorum communis in all examined forearms (Fig. 2). On the other hand, in the method proposed in this study, the EI is superficial in all subjects as confirmed by a cross-sectional view (Fig. 1B). If the needle is inserted at a superficial point, it is possible to better palpate the muscle and place the needle more precisely. Also, less pain occurs when the muscle is contracted with the needle in place. Points A, B, and C did not provide accurate horizontal distances, but in our method, the horizontal position is presented as a ratio of forearm circumference and is applicable regardless of height. Safwat and Abdel-Meguid [19] demonstrated that the motor point of the EI is in the middle third in 100% of cases. Thus, there is a high possibility of needle placement at the motor point during insertion in MP. However, the needle is inserted at the distal EI at points A and C, making it difficult to position the needle at the motor point. Given these advantages, it is better to insert needles in MP than by using conventional methods.
The current study demonstrated that the horizontal distance of the optimal insertion point was about 8.1% of the forearm circumference in all height groups. However, it is difficult and time consuming to calculate the percentage of forearm circumference in a clinical setting. Post-hoc test showed that there was no significant difference in MP-X between the 150s and 160s groups, 160s and 170s groups, and 170s and 180s groups. The difference in average of MP-X (about 0.9 cm) between the 160s and 170s groups was larger than the differences between the other groups, and the corresponding p-value was also the largest. Thus, it may be a good alternative to apply the average MP-X above and below a height cutoff value of 170 cm. Thus, 1.3 cm radial from the medial border of the ulna can be applied to the under-170 cm group and 1.5 cm can be used in the over-170 cm group as the horizontal distance of MP.
In this study, the average MP-Y and Y ratio of all participants were about 5.5 cm and 22%. MP-Y shows significant differences between height groups. Unlike MP-X, there were also significant differences in MP-Y between all adjacent groups. Therefore, it is difficult to suggest MP-Y as absolute value, not as percentage. However the absolute value is easier to apply in the clinical practice than a percentage of forearm length so further studies about the novel method that can propose the horizontal distance as absolute value are needed.
Im et al. [2] proposed that the midpoint of the EI is an appropriate needle insertion point in a cadaveric study. They suggested the position of the midpoint at about 4.8 cm (about 21.1% of the forearm length) proximal from the ulnar styloid process and about 0.7 cm (about 12.6% of the forearm width at the midpoint) from the medial border of the ulna. By our calculations, the MP-Y was about 5.5 cm, which was different from theirs, but the ratio of MP-Y to forearm length was 22.0%, which was similar. The difference between these studies might be attributable to a change in the length and thickness of the muscles during the process of embalming the cadavers.
In addition, the previous study did not include cadavers with various heights, so a selection bias may have occurred. In the cadaveric study, the horizontal distance of the midpoint was presented as a straight line rather than a circumference, which makes it difficult to compare directly with the MP-X. In actual clinical trials, it is difficult to use the linear distance during needle insertion and it is more useful to use the circumference. The depth is important for accurate needle insertion into the muscles of the forearm, which has many small muscles with multiple layers, but the previous study did not investigate depth. The styloid process of the ulna was used as the landmark for vertical distance in the cadaveric study. However, the location of the ulnar styloid process can be confusing because the ulnar styloid process can be located on either the volar or dorsal side when the forearm is pronated or supinated [20] and may not be palpable in some people. The ulnar head, on the other hand, is easily palpable in most people, even overweight people, regardless of posture and is the most prominent structure in the wrist, making it a better landmark.
There were several limitations of this study. The subjects did not include people with other diseases such as neurologic lesions or strokes. Muscle atrophy due to denervation can occur in patients with neurologic lesions and disuse atrophy can occur in stroke patients. If such morphologic changes occur, accurate needle insertion may be difficult with the method presented in this study. Future studies are needed to target patients with various diseases and conduct subgroup analysis. Second, variations in the EI have been reported in some studies. According to several previous studies, there are extensor medii proprius or digiti, extensor indicis et medii communis or digiti, extensor pollicis et indicis, and extensor indicis ulnaris and radialis muscles [21,22]. In people with these variations, it may be difficult to identify the optimal insertion point using our method. In the present study, there were no participants with variations of the EI. Third, in the present study, the total mean BMI was 22.5±2.7 kg/m2 and the range was 17.5–29.3 kg/m2. Although participants with a variety of BMIs enrolled in the study, the depth of needle insertion may vary in extremely overweight or underweight people. Future studies should include a more varied population. Lastly, the nerves and blood vessels adjacent to the EI were not considered in the current study. The posterior interosseous artery and posterior interosseous nerve pass around the EI. Therefore, a safer needle insertion method could be suggested by analyzing the locational relationship between MP and the surrounding vessels or nerves.
In conclusion, various needle insertion methods for the EI have been proposed, but each has several limitations. In this study, we propose a new and accurate needle insertion method for the EI using ultrasound. The optimal needle placement point for EI, which avoids penetrating other muscles, lies at approximately 22% of the forearm length from the lower margin of the ulnar head and approximately 8.1% of the forearm circumference from the medial border of the ulna at a depth of 7.6 mm. We hope that this method will provide more accurate needle EMG or injection treatment for the EI.
Acknowledgements
This work was supported by the Soonchunhyang University Research Fund.
Notes
No potential conflict of interest relevant to this article was reported.
Conceptualization: Lee HJ, Han ZA. Methodology: Lee HJ, Kim HY, Kim TL, Ham DH. Formal analysis: Lee HJ, Kim HY, Kim EY, Son MK, Lee JJ, Kim TY. Project administration: Lee HJ, Kim HY. Visualization: Lee HJ, Kim HY, Sung JH. Writing – original draft: Lee HJ, Kim HY. Writing – review and editing: Lee HJ, Kim HY, Shin JW. Approval of final manuscript: all authors.