Original Articles
Ultrasonographic Analysis of Optimal Needle Placement for Extensor Indicis
Jin Young Kim, Hyun Seok, Sang-Hyun Kim, Yoon-Hee Choi, Jun Young Ahn, Seung Yeol Lee
Ann Rehabil Med 2020;44(6):450-458.   Published online December 31, 2020
DOI: https://doi.org/10.5535/arm.20035
Objective
To determine the most optimal needle insertion point of extensor indicis (EI) using ultrasound.
Methods
A total 80 forearms of 40 healthy volunteers were recruited. We identified midpoint (MP) of EI using ultrasound and set MP as optimal needle insertion point. The location of MP was suggested using distances from landmarks. Distance from MP to medial border of ulna (MP-X) and to lower margin of ulnar head (MP-Y) were measured. Ratios of MP-X to Forearm circumference (X ratio) and MP-Y to forearm length (Y ratio) were calculated. In cross-sectional view, depth of MP (Dmp), defined as middle value of superficial depth (Ds) and deep depth (Dd) was measured and suggested as proper depth of needle insertion.
Results
Mean MP-X was 1.37±0.14 cm and mean MP-Y was 5.50±0.46 cm. Mean X ratio was 8.10±0.53 and mean Y ratio was 22.15±0.47. Mean Dmp was 7.63±0.96 mm.
Conclusion
We suggested that novel optimal needle insertion point of the EI. It is about 7.6 mm in depth at about 22% of the forearm length proximal from the lower margin of the ulnar head and about 8.1% of the forearm circumference radial from medial border of ulna.
  • 5,073 View
  • 175 Download
Optimal Placement of Needle Electromyography in Extensor Indicis: A Cadaveric Study
Jin Young Im, Hong Bum Park, Seok Jun Lee, Seong Gyu Lim, Ki Hoon Kim, Dasom Kim, Im Joo Rhyu, Byung Kyu Park, Dong Hwee Kim
Ann Rehabil Med 2018;42(3):473-476.   Published online June 27, 2018
DOI: https://doi.org/10.5535/arm.2018.42.3.473
Objective
To identify the center of extensor indicis (EI) muscle through cadaver dissection and compare the accuracy of different techniques for needle electromyography (EMG) electrode insertion.
Methods
Eighteen upper limbs of 10 adult cadavers were dissected. The center of trigonal EI muscle was defined as the point where the three medians of the triangle intersect. Three different needle electrode insertion techniques were introduced: M1, 2.5 cm above the lower border of ulnar styloid process (USP), lateral aspect of the ulna; M2, 2 finger breadths (FB) proximal to USP, lateral aspect of the ulna; and M3, distal fourth of the forearm, lateral aspect of the ulna. The distance from USP to the center (X) parallel to the line between radial head to USP, and from medial border of ulna to the center (Y) were measured. The distances between 3 different points (M1– M3) and the center were measured (marked as D1, D2, and D3, respectively).
Results
The median value of X was 48.3 mm and that of Y was 7.2 mm. The median values of D1, D2 and D3 were 23.3 mm, 13.3 mm and 9.0 mm, respectively.
Conclusion
The center of EI muscle is located approximately 4.8 cm proximal to USP level and 7.2 mm lateral to the medial border of the ulna. Among the three methods, the technique placing the needle electrode at distal fourth of the forearm and lateral to the radial side of the ulna bone (M3) is the most accurate and closest to the center of the EI muscle.

Citations

Citations to this article as recorded by  
  • Ultrasonographic Analysis of Optimal Needle Placement for Extensor Indicis
    Jin Young Kim, Hyun Seok, Sang-Hyun Kim, Yoon-Hee Choi, Jun Young Ahn, Seung Yeol Lee
    Annals of Rehabilitation Medicine.2020; 44(6): 450.     CrossRef
  • 9,764 View
  • 138 Download
  • 1 Web of Science
  • 1 Crossref
TOP