• KARM
  • Contact us
  • E-Submission
ABOUT
ARTICLE TYPES
BROWSE ARTICLES
AUTHOR INFORMATION

Page Path

1
results for

"Sung Dong Kim"

Filter

Article category

Keywords

Publication year

Authors

Funded articles

"Sung Dong Kim"

Original Article
What is the Adequate Cuff Volume for Tracheostomy Tube? A Pilot Cadaver Study
Dong Min Kim, Myung Jun Shin, Sung Dong Kim, Yong Beom Shin, Ho Eun Park, Young Mo Kim, Jin A Yoon
Ann Rehabil Med 2020;44(5):402-408.   Published online September 28, 2020
DOI: https://doi.org/10.5535/arm.19210
Objective
To determine the patterns of tracheostomy cuff pressure changes with various air inflation amounts in different types of tracheostomy tubes to obtain basic data for appropriately managing longterm tracheostomy.
Methods
We performed tracheostomy on a 46-year-old male cadaver. Three types of tracheostomy tubes (single-cuffed, double-cuffed, and adjustable flange), divided into 8 different subtypes based on internal tube diameters and cuff diameters, were inserted into the cadaver. Air was inflated into the cuff, and starting with 1 mL air, the cuff pressure was subsequently measured using a manometer.
Results
For the 7.5 mm/14 mm tracheostomy tube, cuff inflation with 3 mL of air yielded a cuff pressure within the recommended range of 20–30 cmH2O. The 7.5 mm/24 mm tracheostomy tube showed adequate cuff pressure at 5 mL of air inflation. Similar values were observed for the 8.0 mm/16 mm and 8.0 mm/27 mm tubes. Double-cuffed tracheostomy cuff pressures (7.5 mm/20 mm and 8.0 mm/20 mm tubes) at 3 mL air inflation had cuff pressures of 18–20 cmH2O at both the proximal and distal sites. For the adjustable flange tracheostomy tube, cuff pressure at 6 mL of cuff air inflation was within the recommended range. Maximal cuff pressure was achieved at inflation with almost 14 mL of air, unlike other tube types.
Conclusion
Various types of tracheostomy tubes showed different cuff pressures after inflation. These values might aid in developing guidelines For patients who undergo tracheostomy and are discharged home without cuff pressure manometers, this standard might be helpful to develop guidelines.

Citations

Citations to this article as recorded by  
  • Tracheotomy
    Daniel Gorelik, Yixuan James Zheng, Franklin Wu, Ran A. Wang
    Medical Clinics of North America.2026; 110(1): 103.     CrossRef
  • Fluid-Filled Tracheal Tube Cuffs: Implications for Speech, Sealing, and Safety
    Thomas C. Blakeman
    Respiratory Care.2025; 70(7): 930.     CrossRef
  • Impact of Low‐Volume, Low‐Pressure Tracheostomy Cuffs on Acute Mucosal Injury in Swine
    Alexandra J. Berges, Ioan A. Lina, Rafael Ospino, Hsiu‐Wen Tsai, Dacheng Ding, Jessica M. Izzi, Alexander T. Hillel
    Otolaryngology–Head and Neck Surgery.2022; 167(4): 716.     CrossRef
  • 11,762 View
  • 176 Download
  • 3 Web of Science
  • 3 Crossref
TOP