• KARM
  • Contact us
  • E-Submission
ABOUT
ARTICLE TYPES
BROWSE ARTICLES
AUTHOR INFORMATION

Page Path

1
results for

"Eun Sun Lee"

Filter

Article category

Publication year

"Eun Sun Lee"

Original Article
Accuracy of Heart Rate Measurement Using Smartphones During Treadmill Exercise in Male Patients With Ischemic Heart Disease
Eun Sun Lee, Jin Seok Lee, Min Cheol Joo, Ji Hee Kim, Se Eung Noh
Ann Rehabil Med 2017;41(1):129-137.   Published online February 28, 2017
DOI: https://doi.org/10.5535/arm.2017.41.1.129
Objective

To evaluate the accuracy of a smartphone application measuring heart rates (HRs), during an exercise and discussed clinical potential of the smartphone application for cardiac rehabilitation exercise programs.

Methods

Patients with heart disease (14 with myocardial infarction, 2 with angina pectoris) were recruited. Exercise protocol was comprised of a resting stage, Bruce stage II, Bruce stage III, and a recovery stage. To measure HR, subjects held smartphone in their hands and put the tip of their index finger on the built-in camera for 1 minute at each exercise stage such as resting stage, Bruce stage II, Bruce stage III, and recovery stage. The smartphones recorded photoplethysmography signal and HR was calculated every heart beat. HR data obtained from the smartphone during the exercise protocol was compared with the HR data obtained from a Holter electrocardiography monitor (control).

Results

In each exercise protocol stage (resting stage, Bruce stage II, Bruce stage III, and the recovery stage), the HR averages obtained from a Holter monitor were 76.40±12.73, 113.09±14.52, 115.64±15.15, and 81.53±13.08 bpm, respectively. The simultaneously measured HR averages obtained from a smartphone were 76.41±12.82, 112.38±15.06, 115.83±15.36, and 81.53±13 bpm, respectively. The intraclass correlation coefficient (95% confidence interval) was 1.00 (1.00–1.00), 0.99 (0.98–0.99), 0.94 (0.83–0.98), and 1.00 (0.99–1.00) in resting stage, Bruce stage II, Bruce stage III, and recovery stage, respectively. There was no statistically significant difference between the HRs measured by either device at each stage (p>0.05).

Conclusion

The accuracy of measured HR from a smartphone was almost overlapped with the measurement from the Holter monitor in resting stage and recovery stage. However, we observed that the measurement error increased as the exercise intensity increased.

Citations

Citations to this article as recorded by  
  • SPECIAL ISSUE: Improve Client Care by Dispelling HRV Myths
    Fred Shaffer, Zachary Meehan
    Biofeedback.2024; 52(2): 29.     CrossRef
  • Cardiac rehabilitation engagement and associated factors among heart failure patients: a cross-sectional study
    Tianxi Yu, Min Gao, Guozhen Sun, Guendalina Graffigna, Shenxinyu Liu, Jie Wang
    BMC Cardiovascular Disorders.2023;[Epub]     CrossRef
  • Deep Learning-Based Optimal Smart Shoes Sensor Selection for Energy Expenditure and Heart Rate Estimation
    Heesang Eom, Jongryun Roh, Yuli Sun Hariyani, Suwhan Baek, Sukho Lee, Sayup Kim, Cheolsoo Park
    Sensors.2021; 21(21): 7058.     CrossRef
  • “Weighing Cam”: A New Mobile Application for Weight Estimation in Pediatric Resuscitation
    Joong Wan Park, Hyuksool Kwon, Jae Yun Jung, Yoo Jin Choi, Ji Soo Lee, Woo Sang Cho, Jung Chan Lee, Hee Chan Kim, Se Uk Lee, Young Ho Kwak, Do Kyun Kim
    Prehospital Emergency Care.2020; 24(3): 441.     CrossRef
  • Ambient assistance service for fall and heart problem detection
    Amina Makhlouf, Isma Boudouane, Nadia Saadia, Amar Ramdane Cherif
    Journal of Ambient Intelligence and Humanized Computing.2019; 10(4): 1527.     CrossRef
  • The Current State of Mobile Phone Apps for Monitoring Heart Rate, Heart Rate Variability, and Atrial Fibrillation: Narrative Review
    Ka Hou Christien Li, Francesca Anne White, Timothy Tipoe, Tong Liu, Martin CS Wong, Aaron Jesuthasan, Adrian Baranchuk, Gary Tse, Bryan P Yan
    JMIR mHealth and uHealth.2019; 7(2): e11606.     CrossRef
  • VALIDATION OF SMARTPHONE FREE HEART RATE MONITORING APPLICATION DURING TREADMILL EXERCISE
    Zulkarnain Jaafar, Aravind Kumar Murugan
    Revista Brasileira de Medicina do Esporte.2019; 25(2): 112.     CrossRef
  • Putting the data before the algorithm in big data addressing personalized healthcare
    Eli M. Cahan, Tina Hernandez-Boussard, Sonoo Thadaney-Israni, Daniel L. Rubin
    npj Digital Medicine.2019;[Epub]     CrossRef
  • Point-of-care technologies in heart, lung, blood and sleep disorders from the Center for Advancing Point-of-Care Technologies
    Eric Y. Ding, Emily Ensom, Nathaniel Hafer, Bryan Buchholz, Mary Ann Picard, Denise Dunlap, Eugene Rogers, Carl Lawton, Ainat Koren, Craig Lilly, Timothy P. Fitzgibbons, David D. McManus
    Current Opinion in Biomedical Engineering.2019; 11: 58.     CrossRef
  • Utilización de smartphone en los programas de rehabilitación cardíaca. Una revisión sistemática
    A. Muzas Fernández, M. Soto González
    Rehabilitación.2018; 52(4): 238.     CrossRef
  • Real-Time Monitoring in Home-Based Cardiac Rehabilitation Using Wrist-Worn Heart Rate Devices
    Javier Medina Quero, María Rosa Fernández Olmo, María Dolores Peláez Aguilera, Macarena Espinilla Estévez
    Sensors.2017; 17(12): 2892.     CrossRef
  • 9,665 View
  • 77 Download
  • 9 Web of Science
  • 11 Crossref
TOP