Ji Hoon Lee | 3 Articles |
To assess the practical diagnostic value of facial nerve antidromic evoked potential (FNAEP), we compared it with the diagnostic value of the electroneurography (ENoG) test in Bell's palsy. In total, 20 patients with unilateral Bell's palsy were recruited. Between the 1st and 17th days after the onset of facial palsy, FNAEP and ENoG tests were conducted. The degeneration ratio and FNAEP latency difference between the affected and unaffected sides were calculated in all subjects. In all patients, FNAEP showed prolonged latencies on the affected side versus the unaffected side. The difference was statistically significant. In contrast, there was no significant difference between sides in the normal control group. In 8 of 20 patients, ENoG revealed a degeneration ratio less than 50%, but FNAEP show a difference of more than 0.295±0.599 ms, the average value of normal control group. This shows FNAEP could be a more sensitive test for Bell's palsy diagnosis than ENoG. In particular, in 10 patients tested within 7 days after onset, an abnormal ENoG finding was noted in only four of them, but FNAEP showed a significant latency difference in all patients at this early stage. Thus, FANEP was more sensitive in detecting facial nerve injury than the ENoG test (p=0.031). FNAEP has some clinical value in the diagnosis of facial nerve degeneration. It is important that FNAEP be considered in patients with facial palsy at an early stage and integrated with other relevant tests. Citations Citations to this article as recorded by
To evaluate intra-tester reliability of P300 more precisely, this study was designed. Event-related potential (ERP) is the result of endogenous brain response following cognitive stimulus. The P300 component of the human ERP is a positive wave with a latency of 300 ms or greater. Our purpose of this study was to estimate reliability of P300 latency and amplitude with 30 normal persons without head injury, as well as to set up them as the reference values in the event that they would be found to be highly reliable. ERP was performed at three separate times on 30 normal adults in their 20s and 30s. We measured P300 latency and amplitude among ERP. P300 latency show excellent reliability with intraclass correlation coefficient (ICC) of 0.81. As to P300 amplitude, reliability was good to fair with ICC of 0.53. Average value of P300 latency was 311.3±37.0 ms, shorter than reference value of previous study in Korea. P300 latency revealed higher reliability than P300 amplitude, although reliability of P300 was confirmed in both component. After further study including precise mechanism, influence factor on measurement and method standardization, it is expected to be an objective indicator to assess the cognitive state and predict prognosis. Citations Citations to this article as recorded by
True neurogenic thoracic outlet syndrome (TOS) is an uncommon disease and is difficult to diagnose at the early stage and then completely cure. We experienced a case of true neurogenic TOS with typical clinical symptoms and electrophysiologic findings as a result of repetitive habitual sleep posture. A 31-year-old woman who had complained of progressive tingling sensation on the 4th and 5th fingers with shoulder pain was diagnosed of brachial plexopathy at the lower trunk level by electrodiagnostic studies. There was no other cause of brachial plexopathy except her habit of hyperabduction of shoulder during sleep. This case demonstrated that the habitual abnormal posture can be the only major cause of neurogenic TOS. It is of importance to consider TOS with the habitual cause because simple correction of the posture could stabilize or even reverse disease progress. Citations Citations to this article as recorded by
|