Jae Yong Jeon | 2 Articles |
![]()
Objective
To determine whether the bioimpedance analysis (BIA) ratios of upper to lower extremities could predict treatment outcomes after complex decongestive therapy (CDT) for gynecological cancer related lymphedema (GCRL). Methods A retrospective study, from March 2015 to December 2018, was conducted. The study sample comprised patients receiving CDT, 30 minutes per day, for 10 days. Bioimpedance was measured pre- and post-CDT. Circumference measurements were obtained at 20 and 10 cm above the knee (AK) and 10 cm below the knee (BK). We calculated the expected impedance at 0 Hz (R0) of extremities and upper/lower extremity R0 ratios (R0U/L). We evaluated the relationship between R0U/L and changes in R0U/L and circumferences, pre- and post-CDT. Results Overall, 59 patients were included in this study. Thirty-one lower extremities in 26 patients comprised the acute group, and 38 lower extremities in 33 patients comprised the chronic group. Pre-treatment R0U/L was significantly correlated with R0U/L change after adjusting for age and BMI (acute: R=0.513, p<0.01; chronic: R=0.423, p<0.01). In the acute group, pre-treatment R0U/L showed a tendency to be correlated with circumference change (AK 20 cm: R=0.427, p=0.02; AK 10 cm: R=0.399, p=0.03). Conclusion Our study results suggested that pre-treatment BIA could predict volume reductions after CDT in the early stages of GCRL. These findings implied that BIA value could be one possible parameter to apply in treatment outcomes prediction, during the early stage of GCRL. Therefore, further large-scale prospective studies will be beneficial. Citations Citations to this article as recorded by
To investigate the usefulness of bioimpedance measurement for predicting the treatment outcome in breast cancer related lymphedema (BCRL) patients. Unilateral BCRL patients who received complex decongestive therapy (CDT) for 2 weeks (5 days per week) were enrolled in this study. We measured the ratio of extracellular fluid (ECF) volume by using bioelectrical impedance spectroscopy (BIS), and single frequency bioimpedance analysis (SFBIA) at a 5 kHz frequency before treatment. Arm circumferences were measured at 10 cm above and below the elbow before and after treatment. We also investigated whether there is correlation between ECF ratio and SFBIA ratio with the change of arm circumference after CDT. A total of 73 patients were enrolled in this study. The higher ECF ratio was significantly correlated with higher reduction of arm circumference at both above and below the elbow after treatment, but the higher SFBIA ratio was correlated only with the higher reduction of arm circumference below the elbow. These results show that ECF volume measurements and SFBIA before treatment are useful tools for predicting the outcome of patients with lymphedema. We concluded that ECF volume measure can be used as a screening tool for predicting treatment outcome of BCRL patients. Citations Citations to this article as recorded by
|